Table 6-8. Composite Clock Input Module Alarm and Event Messages
Alarm/
Event/
Trap ID
Typical Alarm/Event/Trap
Response
Description/
Corrective Action
000
LOS, Active
No CC signal.
003
BPV, Active
Invalid BPV density.
006
Hdw Config, Fault
Input module can be installed only in the Main shelf.
If module is installed in slot previously used by a different module
type, use the CONF xAy REMOVE command.
Call Symmetricom Global Services.
007
Phase Hdw, Fault
One of the clock PLLs is not locked.
008
Phase 3Sigma, Fault
Check incoming signal quality.
The phase measurements are invalid or missing.
009
Phase Polarity, Event
The input signal is unstable.
129
Install, CC Input Module
The Input module has been installed.
130
Remove, CC Input Module
The Input module has been removed.
131
Enable, CC Input Module,
COML
The Input module has been enabled.
132
Disable, CC Input Module,
COML
The Input module has been disabled.
133
Restart, in 5 seconds, COML
Module re-boot.
134
Cannot Enable, CC Input
Module, COML
Internal firmware conflict. Restart module; if the problem persists,
call Symmetricom Global Services.
144
Zero Phase, B, COML
A user has forced the phase to be cleared.
146
OutofWindow, Positive BPV
Positive BPV reversed.
147
Sync Clk-C, Start
Start syncing clock C to selected clock.
148
Operating Mode, Subtending
Subtending mode is enabled.
199
Port, Disable, COML
A user has Enabled | Disabled input port.
201
Priority, 5, COML
A user has changed input priority level.
203
Prov PQL, 5, COML
A user has changed input provisioned PQL.
207
Err Cnt, BPV, 16, COML
Signal Alarm Error Count (LOS, AIS, OOF, BPV, or CRC).