Properties
The network configuration may be viewed in a summary form under the
Properties
selection.
Network Settings
The network settings must be established for the clock to operate on the network. You must be a
network administrator or have their support to complete these functions. Your network administrator
determines the information for the Network Settings.
[Note: The default factory setting for network configuration is to use DHCP/BOOTP.]
[Note: If a DHCP server cannot be found on the network by the ND clock, the IP address will be
assigned a fallback IP address of 169.254.xxx.xxx]
To utilize static IP addressing, de-select the checkbox for “Automatically obtain network configuration
from DHCP/BOOTP”. You must enter the IP address, Netmask, Gateway, Primary DNS, and may
enter a Secondary DNS.
[Note: The static IP address you enter must not be in use by another device on the network, this includes
IP address ranges reserved for use by the DHCP server. If a static IP address is used which creates a