background image

2 of 6

QUICK START GUIDE:

 T-10 Glass Touchscreen

Wall Mount Installation Instructions

www.symetrix.co 

| +1.425.778.7728

PN 53-0088 Rev A 05/22

Optional, if portrait mounting the touchscreen, remove the 

4 screws on the T-10 Glass rear panel support bracket. 

Rotate the support bracket 90 degrees so the RJ-45 

points down in the desired orientation and ensure the 

indicated notch in the support bracket is pointed down. 

Take care not to disconnect or strain the internal cables 

when rotating the bracket. Reattach with the same 

screws. The same steps can be performed to convert a 

portrait screen back to landscape.

Screw the universal flush mount wall bracket into the wall 

mounted back box using the appropriate screws for US or 

EU boxes as shown below.

1.

Connect the CAT5/6 cable to the T-10 Glass touchscreen.

3.

2.

Attach the T-10 Glass touchscreen onto the universal 

flush mount wall bracket by first hooking the snaps on 

the touchscreen rear panel onto the top tabs of the 

wall bracket. Then press the bottom of the touchscreen 

enclosure to snap the bottom hooks onto the tabs of the 

wall bracket.

4.

Summary of Contents for T-10 Glass

Page 1: ...14 Unplug this apparatus during lightning storms or when unused for long periods of time 15 Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug cord is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate norm...

Page 2: ...rain the internal cables when rotating the bracket Reattach with the same screws The same steps can be performed to convert a portrait screen back to landscape Screw the universal flush mount wall bracket into the wall mounted back box using the appropriate screws for US or EU boxes as shown below 1 Connect the CAT5 6 cable to the T 10 Glass touchscreen 3 2 Attach the T 10 Glass touchscreen onto t...

Page 3: ...unt bracket depending on which surface will be rested upon 2 Attach the universal flush mount wall bracket to the upper and lower table mount stand sections using the eight 8 included 6 32 x screws as shown in the image on the left 1 5 To remove the T 10 Glass from the universal wall mount bracket insert a pry tool e g flat head screwdriver between the universal wall mount bracket and the support ...

Page 4: ... in the range of 169 254 x x with a Subnet Mask of 255 255 0 0 in order to communicate with T 10 Glass touchscreen in a direct connect mode However if your PC is using the default network settings it should also have automatically self assigned a similar private IP address in the range of 169 254 x x and if this is the case you should be able to connect to T 10 Glass touchscreen directly Even if t...

Page 5: ...onformity We Symetrix Incorporated 6408 216th St SW Mountlake Terrace Washington USA declare under our sole responsibility that the product T 10 Glass to which this declaration relates is in conformity with the following standards EN 55032 FCC Part 15 EMC USA EN 301 489 17 V3 2 4 2020 09 The technical construction file is maintained at Symetrix Inc 6408 216th St SW Mountlake Terrace WA 98043 USA T...

Page 6: ... has occurred due to a defect in materials or workmanship within the warranty period 7 Conditions caused by normal wear and tear or otherwise due to the normal aging of Symetrix products 8 Damage caused by use with another product 9 Product on which any serial number has been removed altered or defaced 10 Product that isn t sold by an authorized Symetrix Dealer or Distributor Buyer Responsibilitie...

Reviews: