4-22
LT 1804 Product Reference Guide: Programming the LT 1804
Software Handshaking
The scanner also provides two software handshaking options, ENQ and ACK/
NAK, selected by parameter menus.
These software handshaking options operate in addition to, and are
subordinate to, the hardware handshaking. They can be used separately, in
conjunction with each other, or not at all. They operate in the following
manner:
•
When the ENQ is enabled, the scanner waits for an ENQ, Enquire,
character from the host before it transmits data. The host must respond
within the programmable response timeout period or the scanning unit
beeps 4 times, indicating transmission error and loss of the last scanned
data.
•
When the ACK/NAK is enabled, after the scanning unit has transmitted
data, it looks for one of the following responses:
<ACK> acknowledging a valid accepted transmission, or
<NAK> indicating a problem with the transmission.
The scanner then retransmits the data. After three unsuccessful
transmission attempts, the unit aborts any further communication
attempts on the current message. It indicates this by sounding 4 long
(1 second) beeps.
See
Handshaking Sequence on page 4-23
.
Summary of Contents for LT 1804
Page 82: ...5 27 LT 1804 Product Reference Guide Parameter Menus Baud Rate Continued 4800 1200 2400 9600 ...
Page 102: ...5 47 LT 1804 Product Reference Guide Parameter Menus Prefix Continued 0 1 2 NONE STX ...
Page 103: ...5 48 LT 1804 Product Reference Guide Parameter Menus Prefix Continued 5 3 4 6 7 ...
Page 107: ...5 52 LT 1804 Product Reference Guide Parameter Menus Suffix Continued 2 0 1 3 ...
Page 108: ...5 53 LT 1804 Product Reference Guide Parameter Menus Suffix Continued 5 4 6 7 ...