4-15
LT 1804 Product Reference Guide: Programming the LT 1804
RS-232 Host Type Defaults
Three RS-232C hosts are set up with their own parameter default settings
(
). Selecting the ICL, Fujitsu, or Nixdorf RS-232C terminal sets the
defaults listed below. These defaults take precedence over standard defaults.
So if you select Fujitsu RS-232C, then select the standard defaults, the Fujitsu
defaults still take precedence.
Table 4-2. Terminal-Specific RS-232C Defaults
Parameter
Standard
ICL
FUJITSU
NIXDORF
Mode A/
Mode B
Transmit Code ID
No
Yes
Yes
Yes
Data Transmission Format
Data as is
Data/Suffix
Data/Suffix
Data/Suffix
Suffix
CR/LF (7013)
CR (1013)
CR (1013)
CR (1013)
Baud Rate
9600
9600
9600
9600
Parity
None
Even
None
Odd
Hardware Handshaking
None
RTS/CTS
Option 3
None
RTS/CTS
Option 3
Software Handshaking
None
None
None
None
Serial Response Time-out
2 Sec.
9.9 Sec.
2 Sec.
9.9 Sec.
Stop Bit Select
One
One
One
One
ASCII Format
8-Bit
8-Bit
8-Bit
8-Bit
Beep On <BEL>
Disabled
Disabled
Disabled
Disabled
RTS Line State
Low
High
Low
*Low = No
data to send
*In the Nixdorf Mode B, if CTS is Low, scanning is disabled. When CTS is High, the user can scan
bar codes.
Summary of Contents for LT 1804
Page 82: ...5 27 LT 1804 Product Reference Guide Parameter Menus Baud Rate Continued 4800 1200 2400 9600 ...
Page 102: ...5 47 LT 1804 Product Reference Guide Parameter Menus Prefix Continued 0 1 2 NONE STX ...
Page 103: ...5 48 LT 1804 Product Reference Guide Parameter Menus Prefix Continued 5 3 4 6 7 ...
Page 107: ...5 52 LT 1804 Product Reference Guide Parameter Menus Suffix Continued 2 0 1 3 ...
Page 108: ...5 53 LT 1804 Product Reference Guide Parameter Menus Suffix Continued 5 4 6 7 ...