B-5
FMT 3000 Hardware Reference Manual - Specifications
Compliance Testing
FCC
A single FMT 3000 unit, representative of a typical production unit, will be sent for FCC
compliance testing. Units will not be available for sale until successfully passing class A
(industrial) requirements.
European Union Compliance:
Extended Burn-in
FMT 3000 units, representative of typical production units, will be powered and placed at
50˚C for not less than 1000 device hours. Successful operation of 1000 device hours at 50˚C
is required prior to manufacturing release.
Environmental/Endurance Testing
MTBF Calculation - IL_HDBK-217E, ground fixed, 0, 25˚C and 50˚C
Package Drop Test - Standard TBD
Functional test 0-50˚C in temperature chamber
No other environmental testing of the FMT 3000 is required.
Test
Level
Description
EN55022
Class A
Light Industrial
IEC 801-2 ESD
3
15 kV air discharge
IEC 801-3 Radiated Susceptibility 2
3 V/m
IEC801-4 Fast Transient Burst
2
1kV@5Khz, power supply 0.5 kV @ 5 khz, I/O and signal
IEC 1000-5 Surge Immunity
2
1 kV