Monitor Mode Set
17
DISPLAY
Individual Set
You can set the title, dwell, alarm, load and audio input
for quad in individual mode.
1
Turn the power on to all devices used.
2
Press the MENU button, the initial MENU is displayed.
√
mark is located in “Monitor Mode Set”.
3
Press the SHIFT
button, the MONITOR MODE SET
menu is displayed.
4
Press the SHIFT
button until
√
mark is located in
“Individual Set”. Press the SHIFT
button, the
INDIVIDUAL SET menu is displayed
4
Press the SET – (or +) button to set the modes you
want.
The modes are changed described below.
Title ..............A maximum of 8 characters can be used in
title mode. (letters, numbers or spaces)
Dwell ............03S
➝
04S
➝
05S
➝
...
➝
30S
➝
OFF
➝
01S
➝
02S
➝
03S ...
Alarm............N/O
➝
OFF
➝
N/C
➝
N/O ...
Load..............75
➝
HI
➝
75...
QUAD............03S
➝
04S
➝
05S
➝
...
➝
30S
➝
OFF
➝
01S
➝
02S
➝
03S...
5
Press the MENU button until the normal screen is
displayed. The setting procedure is now complete.
✔
• TITLE: you can enter up to
8 characters for each
camera title.
• DWELL is the amount of
time that a camera is
displayed on the screen
when the system is in the
Automatic sequential
switching mode.
• ALARM: There are three
factors to provide the
alarm positions, Normally
Open (N.O), Normally
Closed (N.C) and OFF.
When you select OFF,
alarm recording won’t be
performed.
• LOAD: The video signal is
normally terminated by
75ohms. But in case the
signal is distributed to a
number of lines, only one
of lines is needed to be
terminated by
75ohms(1Vp-p), while the
other lines are terminated
by High impedance status
(2Vp-p).
16
Monitor Mode Set
magnetic reed switch, etc. to the sensor port on the back
of the cameras or monitor. An audible buzzer for 1 to 60
seconds and an alarm output for 1 to 60 seconds are
provided to alert the user or to activate a recorder. The
trigger signal is sent to the monitor when an alarm is
activated. The picture will be displayed in full screen,
even if the monitor is set to quad mode. When the next
alarm is activated after the first alarm hold time, each
alarm input picture will be displayed sequentially in full
screen and returns to quad mode. Meanwhile, when the
next alarm is activated within the first alarm hold time,
the picture will be displayed in quad mode and the
alarm indicator “A” blinks in each screen during the
alarm setting time. Then the quad mode is
maintained.When a sensor is activated, the unit in the
sequential mode will automatically lock on to the
alarmed camera for 0 to 60 seconds. The set will
automatically return to the QUAD mode after alarm hold
time, 0 to 60 seconds.
7
Press the MENU button until the normal screen is
displayed.
✔
•
Alarm sensor can be
released by pressing MENU
button for 2 seconds.
MONITOR MODE SET
shift:
†
sel:
√
end:MENU
Clock Set
Screen Display Set
√
Individual Set
Motion Set
Picture Set
INDIVIDUAL SET
shift:
†
√
sel: +– end:MENU
TITLE
DWL ALM L/D
√
C1 ---C1--- 03S N/O 75
C2 ---C2--- 03S N/O 75
C3 ---C3--- 03S N/O 75
C4 ---C4--- 03S N/O 75
QUAD
03S
Summary of Contents for SY20C6144-A