![Sylvania SY17TD8144-A Instruction Manual Download Page 18](http://html1.mh-extra.com/html/sylvania/sy17td8144-a/sy17td8144-a_instruction-manual_1417508018.webp)
REC SPEED
:
[60] IPS
Select the images per second (IPS) that the unit will record. Note
that this is an overall value and is split between the active cameras.
Example – 60 IPS / 4 (cameras) = 15 IPS per camera
REC SELECT
:
CH1 – CH4
Each channel may be enabled/disabled from recording using this
option.
HDD CLEAR
ALL
:
[N]
The HDD may be cleared of all data in this section. Press ENTER to
change to [MASTER], and then press the RIGHT button to select
Yes to erase.
HDD
OVERWRITE
:
[N]
This option selects whether the unit will begin overwriting old
information when the HDD fills, or stop recording when the HDD is
full.
HDD SLAVE
:
[N]
Select [Y] is connecting an external slave drive.
9. ALARM REC SET
ALARM REC
:
[N]
Select whether the DVR will begin recording upon an alarm event.
Alarm events include the external activation and or motion detection.
REC QUALITY
:
[BEST
Select the quality setting to be used for alarm recording – [LOW],
[NORMAL], [HIGH], or [BEST]
REC SPEED
:
[60] IPS
Select the images per second (IPS) that the unit will record when
activated. Note that this is an overall value and is split between the
active cameras. Example – 60 IPS / 4 (cameras) = 15 IPS per
camera
REC
DURATION
:
[N]
Select the record duration to be used when an alarm is detected.
Valid entries include – 1/5/15/30 MIN, 1Hr, and Continuous.
10. SCHEDULE REC SET
SCHEDULE REC :
[DAILY] - Recording will be carried out according to time in a daily. Date will be
disregarded.
[OFF] - No schedule.
[ONCE] - Recording will be carried out according to the schedule.
[SCHEDULE REC SET ]
SCHEDULE REC : [ OFF ]
N0 : _ _ / _ _ _ _ : _ _ -> _ _ / _ _ _ _ : _ _
N1 : _ _ / _ _ _ _ : _ _ -> _ _ / _ _ _ _ : _ _
N2 : _ _ / _ _ _ _ : _ _ -> _ _ / _ _ _ _ : _ _
N3 : _ _ / _ _ _ _ : _ _ -> _ _ / _ _ _ _ : _ _
N4 : _ _ / _ _ _ _ : _ _ -> _ _ / _ _ _ _ : _ _
N5 : _ _ / _ _ _ _ : _ _ -> _ _ / _ _ _ _ : _ _
N6 : _ _ / _ _ _ _ : _ _ -> _ _ / _ _ _ _ : _ _
N7 : _ _ / _ _ _ _ : _ _ -> _ _ / _ _ _ _ : _ _
RETURN : { J ]
EXIT : { J ]
11. TFT SET –
Adjust the monitor’s Contrast, Brightness. You will see this menu on your camera
setting rather than on a blue background, enabling you to see the
changes being made to the picture.
Summary of Contents for SY17TD8144-A