![Sylvania SY17TD8144-A Instruction Manual Download Page 16](http://html1.mh-extra.com/html/sylvania/sy17td8144-a/sy17td8144-a_instruction-manual_1417508016.webp)
2. SEQUENCE SET -
QUAD :
03 sec
CH1 :
03 sec
CH2 :
03 sec
CH3 :
03 sec
CH4 :
03 sec
Select the amount of time the unit will stay on each screen
when the unit is in Sequence mode.
Valid dwell times are 00 – 59 seconds. Setting a channel to 00
will remove that channel from the sequence.
3. TITLE SET -
DISPLAY :
[Y]
CH1 :
[CH1]
CH2 :
[CH2]
CH3 :
[CH3]
CH4 :
[CH4]
Select whether the Channel names will appear in the On
Screen Display.
The title for each channel is entered in this section as well.
Each title may be up to 8 characters long.
4. ALARM SET -
The DVR can be triggered externally via 4 Alarm input terminals on the back of the
unit. When triggered, the unit will show ‘AL’ on the display as well as sound the
buzzer if enabled. This alarm may also be used to trigger recording if enabled in
menu #9 -ALARM REC SET.
ALARM :
[OFF]
CH1 :
03 SEC [N/O]
CH2 :
03 SEC [N/O]
CH3 :
03 SEC [N/O]
CH4 :
03 SEC [N/O]
The ALARM enable option may be changed from [OFF] to
[OSD] (On Screen Display) or [OSD + Buzzer].
The alarm duration may be changed for each channel from 01
to 59 seconds.
Also, the input trigger for each channel may be changed from
[N/O] Normally Open, [N/C] Normally Closed or [OFF].
5. MOTION SET –
The DVR has built-in video motion detection. If enabled, a change in the camera
image will cause the unit to register an alarm and show the letters ‘MD’ on the
display. The buzzer will also sound if enabled.
Motion detection can also be used to trigger recording. In order for this to function,
alarm recording must be enabled in menu #9 – ALARM REC SET.
MOTION :
[OFF]
CHANNEL :
[01]
SENSITIVITY :
[03]
AREA :
[00]
The MOTION enable option may be changed from [OFF] to
[OSD] (On Screen Display) or [OSD + Buzzer].
Select the CHANNEL and then adjust the sensitivity and active
area for that camera.
SENSITIVITY may be adjusted from [00-05] where 5 is the most
sensitive.
The AREA may be adjusted to one of 6 detection patterns as
shown below. Select [00] for full screen detection.