Sylvania SIP-S1500M Instruction Manual Download Page 6

6

inSTALLATiOn THROugH SidE Of mASOnRy cHimnEy

1.  Follow L-vent chimney manufacturer’s instructions.
2.  Position the stove, adhering to the clearance in Fig 1 & 2.  Mark the center of the 

hole where the pipe is to pierce the masonry chimney.

3.  It will be necessary to cut out the masonry around the location of the pipe center 

mark.  Cut a 101.6 mm (4 in) diameter hole for 76.2 mm (3 in) pipe and 127 mm 
(5 in) diameter hole for 101.6 mm (4 in) pipe.

4.  Measure and build chimney top plate. Cut out hole for chimney pipe and if used 

for the outside air pipe.

5.  Install the tee on the bottom of the vertical pipe system and lower it down the 

chimney until the center branch of the tee is level with the center of the hole 
in masonry as shown in fig 12.

6.  Install and seal the top plate from step 3 with flexible waterproof sealant.  Slip 

the storm collar over the pipe and while holding the pipe at the proper eleva-
tion, affix the collar with a minimum of three 6.35 mm (1/4 in) stainless steel 
metal screws.  Seal all joints and seams around the collar.

7.  Connect the horizontal pipe by pushing it through the hole in the masonry and 

lining it up with the branch in the tee.  Push the pipe into the tee while twisting it 
to lock the tee.

8.  If needed, once the horizontal pipe is in place, the space between the pipe and 

masonry may be filled with high temperature grout.

9.  Install the trim collar.  An adjustable pipe length and adaptor may be needed to 

align and complete the connection to the stove.

fig. 12

CONNECTION OF COMbUSTION AIR SUppLY

1: Attach Trim Collar to the wall inside the house and attach with 4 screws.
2: Attach Rodent Guard Cover to the wall outside the house and attach with 4 

screws.

3: Attach the Metal Pipe to Air Intake at the back of stove (See Figure 4 for location 

of Air Intake) and attach with Pipe Clamp.

4: Route the Metal Pipe into the wall and fix the other end of Metal Pipe into  

Rodent Guard.

5: Attach the Rodent Guard onto the cover.
6: Attach Exterior Cover to Rodent Guard Cover and attach with 2 screws. 

 

OpERATION: USINg CORRECT FUEL

This stove is designated for burning pelletized wood fuel only.  Pellet of 6.35 mm (1/4 
in) or 21.17 mm (5/6 in) in diameter and approximately 25.4 mm (1 in) long shall be 
used.  Longer or thicker pellets sometime bridge the auger flights, which prevents 
proper pellet feed.  
Burning wood in forms other than pellets is not permitted.  It will violate the building 
codes for which the stove has been approved and will void all warranties.
This stove feed pellets at preset rates, adding fuel by hand will not increase heat 
output but may seriously impair the stove performance by generating considerable 
smoke. 
Do not burn wet pellets.
The stove performance depends heavily on the quality of your pellet fuel.  Avoid the 
use of pellet which is excess fines, with binder and high ash content.

 

LIgHTINg pROCEdURE

 wARning – mAKE SuRE HOPPER Lid And fROnT dOOR Of THE 

STOVE HAVE BEEn TigHTLy cLOSEd BEfORE STARTEd.

A. 

Fill the hopper and clean burn pot.

B. 

Make sure the front door and hopper lid are closed tightly.

C. 

Connect the plug into standard 120Vac, 60 Hz outlet. Press ON/OFF once to 
start lighting.

D. 

The unit has entered the start-up period and pellet is now feeding under the 
preset rate.

E. 

After 5 minutes, the pellet is then burning normally and you can select the 
HEAT LEVEL and BLOWER air flow as below:

 

HEAT 

– Press UP and DOWN button at left side of control panel to select heat 

level. The LED display at left shall show 1 – LOW, 2 – MEDIUM, 3 – HIGH.

 

bLOWER

 – Press UP and DOWN button at right side of control panel to select 

air flow.  The LED at right side shall show 1 –LOW, 2 – MEDIUM, 3 – HIGH. 
 

Summary of Contents for SIP-S1500M

Page 1: ...ARD WARNING KEEP CHILDREN AND ANIMALS AWAY FROM THE FIREPLACE WARNING DO NOT STORE PLACE FLAMMABLE GOODS CLOSE TO FIREPLACE WARNING Restrict the use of this product to persons who read understand and...

Page 2: ...ng on pellet size length and diameter Burn rate Maximum 2 kgs 4 4 lbs BTU range 28000 BTU Electrical rating 120Vac 60Hz Light cycle 410W Continuous cycle 110W IMPORTANT SAFETY INSTRUCTIONS PROFESSIONA...

Page 3: ...l All connections must be secured and made airtight by using either an appropriately sized hose clamp and or UL 181 AP foil tape fig 4 fig 5 If outside air is not used it is important that combustion...

Page 4: ...e the possibility of smoke spillage caused by negative pressure 7 Attach cap and seal outside wall thimbles with non hardening water roof mastic 8 Note Termination should not be located so that hot ex...

Page 5: ...in above the top of chimney 4 Install a blanket plate and the chimney pipe and if used the outside air pipe as shown in Fig 11 5 Attach the DuraVent adaptor a section of pipe and clean out tee make s...

Page 6: ...to Air Intake at the back of stove See Figure 4 for location of Air Intake and attach with Pipe Clamp 4 Route the Metal Pipe into the wall and fix the other end of Metal Pipe into Rodent Guard 5 Attac...

Page 7: ...ch before using vacuum Cleaning 1 Dispose the ash by pulling out the ash drawer Put the ash into air tight metal container and wait for final disposal The metal container or ash shall be placed on a n...

Page 8: ...replace the unit It will have to be returned to us freight prepaid and we will return the repaired or replaced unit to you freight prepaid The company s sole obligation is to repair or replace the un...

Page 9: ...9...

Reviews: