Sylvania SIP-S1500M Instruction Manual Download Page 2

2

11)   Horizontal runs should not exceed 1.2 m (4 ft) with a maximum vertical flue 

height of 10.6 m (35 ft).

12)   This unit should be turned off and allowed to cool prior to cleaning.  Any ashes 

should be kept in an airtight metal container and not disposed of until they are 
completely cooled.

13)   Read the instructions thoroughly and save them for future use.
14)   Do not allow paint, chemicals or construction dust on or near the unit.  Do not 

allow liquid or any foreign materials on or inside your unit.  Shut your unit 
down, let cool and then cover it when painting, during construction or similar 
activity.  Wipe and clean your unit if any foreign material gets on or inside your 
unit. Unplug unit first, and then vacuum and clean the motor and inside of the 
unit.

15)   Improper gasket maintenance, including failure to replace gaskets, can cause 

air leaks resulting in smoke-back problems.

16)   This unit is for residential use only, but is not suitable for mobile homes.

SpECIFICATIONS

Model: .................................................................................................................SIP-S1500M
Width: .............................................................................................................55 cm (21.6 in)  
Depth: .........................................................................................................52.5 cm (20.6 in)
Height: ...........................................................................................................75 cm (29.5 in)
Weight: ........................................................................................................80 kg (176.3 lbs)
Hopper capacity: Up to ..................................................................Up to 22 kgs (48.5 lbs)
(Hopper capacity may vary slightly depending on pellet size, length and diameter)
Burn rate: ..................................................................................... Maximum 2 kgs (4.4 lbs)
BTU range: ............................................................................................................28000 BTU
Electrical rating:............................................................................................... 120Vac, 60Hz
Light cycle: ..................................................................................................................... 410W
Continuous cycle .......................................................................................................... 110W

IMpORTANT SAFETY INSTRUCTIONS

PROFESSIONAL INSTALLATION IS REQUIRED FOR THIS STOVE.
The pellet stove must be electrically grounded in accordance with local codes or 
with National Electrical code ANSI/ NEPA 70 and CSA-C22.1.
This stove is designed for use with pellatized wood only.  DO NOT BURN COAL OR 
WOOD LOGS OF ANY kind. 
This stove shall be operated with power source for the blowers, exhaust system and 
fuel feeding system.
Never block the air supply to or from the stove as it will seriously degrade the 
performance and cause smoking and soot.
Do not burn high ash content pellets because it will rapidly fill up the burning pot 
and affect the combustion.
The unit is not suitable for mobile homes.

pROdUCT LAbELS

 

 wARning - REAd, undERSTAnd And fOLLOw ALL SAfETy LABELS 

And mARKingS On THE uniT. 

ACCESSORIES

See below for accessories included with your unit.

INSTALLATION

Remove the factory packaging and find a suitable location according to the follow-
ing guidelines.

cLEARAncE TO cOmBuSTiBLES 

This stove must be installed with the following minimum clearances to the sides and 
back wall combustible material.  Refer to Fig. 1 for vertical installation and Figure 2 
for vertical corner installation.  

Summary of Contents for SIP-S1500M

Page 1: ...ARD WARNING KEEP CHILDREN AND ANIMALS AWAY FROM THE FIREPLACE WARNING DO NOT STORE PLACE FLAMMABLE GOODS CLOSE TO FIREPLACE WARNING Restrict the use of this product to persons who read understand and...

Page 2: ...ng on pellet size length and diameter Burn rate Maximum 2 kgs 4 4 lbs BTU range 28000 BTU Electrical rating 120Vac 60Hz Light cycle 410W Continuous cycle 110W IMPORTANT SAFETY INSTRUCTIONS PROFESSIONA...

Page 3: ...l All connections must be secured and made airtight by using either an appropriately sized hose clamp and or UL 181 AP foil tape fig 4 fig 5 If outside air is not used it is important that combustion...

Page 4: ...e the possibility of smoke spillage caused by negative pressure 7 Attach cap and seal outside wall thimbles with non hardening water roof mastic 8 Note Termination should not be located so that hot ex...

Page 5: ...in above the top of chimney 4 Install a blanket plate and the chimney pipe and if used the outside air pipe as shown in Fig 11 5 Attach the DuraVent adaptor a section of pipe and clean out tee make s...

Page 6: ...to Air Intake at the back of stove See Figure 4 for location of Air Intake and attach with Pipe Clamp 4 Route the Metal Pipe into the wall and fix the other end of Metal Pipe into Rodent Guard 5 Attac...

Page 7: ...ch before using vacuum Cleaning 1 Dispose the ash by pulling out the ash drawer Put the ash into air tight metal container and wait for final disposal The metal container or ash shall be placed on a n...

Page 8: ...replace the unit It will have to be returned to us freight prepaid and we will return the repaired or replaced unit to you freight prepaid The company s sole obligation is to repair or replace the un...

Page 9: ...9...

Reviews: