Sylvania SIP-S1500M Instruction Manual Download Page 4

4

 cAuTiOn - inSTALL VEnT AT cLEARAncES SPEcifiEd By THE VEnT 

mAnufAcTuRER. 

 wARning – dO nOT inSTALL in BEdROOm. 

 cAuTiOn – THE STRucTuRAL inTEgRiTy Of THE mAnufAcTuREd 

HOmE fLOOR, wALL And cEiLing/ROOf muST BE mAinTAinEd.

EQUIvALENT vENT LENgTH

The longer the run of pipe in your installation, the more restriction there is in the 
system.  Therefore larger diameter pipe should be used for longer runs.
Use 76.2 mm (3 in) pipe if you have less than 4.57 m (15 ft) of equivalent vent length 
(EVL).

To calculate EVL, use the following conversion table:

Qty 

Type of pipe 

EvL (ft)

1  

90 degree elbow or “T” 

5

1  

45 degree elbow 

3

1 ft 

Horizontal pipe run 

1

1ft 

Vertical pipe run 

0.5

Example: (3 x 1.22 m [4ft] of vertical length = 3.66 m [12 ft] x 0.5 = 6 EVL) +  
(1 x elbow or “T” = 5 EVL) + (2 x 0.3 m [1 ft] of horizontal length = 2 EVL)
Total EVL = 13.  So 76.2 mm (3 in) diameter vent is allowed.

note:

 At altitudes more than 914.4 m (3000 ft), we suggest the use of 102 mm (4 in) 

diameter vent at an EVL of 2.13 m (7 ft) or more.

fig. 6

INSTALLATION CONFIgURATION:

Horizontally install through wall

nOTE: fOLLOw L-VEnT cHimnEy mAnufAcTuRER’S inSTRucTiOnS.

1.  Position the stove as Fig 1 & 2 and maintain the clearance specified in Fig. 3.
2.  Determine the position of hole in wall where directly behind stove exhaust vent 

(refer to fig 4).

3.  Always maintain 152.4 mm (6 in) clearance from combustible materials.
4.  Refer to fig 7 for installation.
5.  Install L-vent wall thimble per L-vent manufacturer’s instructions.
6.  Attach enough piping to go through and extend at least 152.4 mm (6 in) beyond 

exterior wall.  An 203.2 m (8 ft) vertical pipe run is suggested where possible to 
reduce the possibility of smoke spillage caused by negative pressure.

7. 

Attach cap and seal outside wall thimbles with non-hardening water-roof mastic.

8.  Note: Termination should not be located so that hot exhaust gases can ignite 

trees, shrubs or grasses or be a hazard to children.  Exhaust gases can reach 
temperatures of 260˚C (500F) and cause serious burns if touched.

9.  Locate terminations: a) not less than 0.91 m (3 ft) above any forced air inlet 

located within 3.05 m (10 ft); b) not less than 1.22 m (4 ft) below or horizontally 
from, or one foot above, any door, window or gravity air inlet into any building; 
c) not less than 0.61 m (2 ft) from an adjacent building and not less than 2.13 m 
(7 ft) above grade when located adjacent to a public walkway.

fig. 7

VERTicALLy wiTH cHimnEy SySTEm

1.  Follow L-Vent chimney manufacturer’s instructions.
2.  Option – to achieve a centered vertical installation, a 45 degree elbow and a 

clean-out tee can be used to offset the pipe from the exhaust outlet to the rear 
center of the stove.

3.  Option – install L-vent elbow in place of clean-out tee. Locate stove. Drop plumb 

bob to center of tee outlet, mark point on ceiling.  Install ceiling support and 
L-vent pipe as per L-vent manufacturer’s instructions.

4.  Always maintain 76.2mm (3 in) clearance from combustible materials. When 

passing through additional floors or ceilings, always install fire-stop spacer.

5.  After liner is up, cut either round or square hole in roof, always 76.2mm (3 in) 

larger all the way around pipe. Install upper edge and sides of flashing under 
roofing materials, nail to the roof along upper edge.  Do not nail lower edge.  
Seal nail heads with flexible waterproof sealant.

6.  Apply flexible, waterproof sealant where the storm collar meets the vent.  Slide 

storm collar down until it sits on the flashing.  Seal and install cap.  

Summary of Contents for SIP-S1500M

Page 1: ...ARD WARNING KEEP CHILDREN AND ANIMALS AWAY FROM THE FIREPLACE WARNING DO NOT STORE PLACE FLAMMABLE GOODS CLOSE TO FIREPLACE WARNING Restrict the use of this product to persons who read understand and...

Page 2: ...ng on pellet size length and diameter Burn rate Maximum 2 kgs 4 4 lbs BTU range 28000 BTU Electrical rating 120Vac 60Hz Light cycle 410W Continuous cycle 110W IMPORTANT SAFETY INSTRUCTIONS PROFESSIONA...

Page 3: ...l All connections must be secured and made airtight by using either an appropriately sized hose clamp and or UL 181 AP foil tape fig 4 fig 5 If outside air is not used it is important that combustion...

Page 4: ...e the possibility of smoke spillage caused by negative pressure 7 Attach cap and seal outside wall thimbles with non hardening water roof mastic 8 Note Termination should not be located so that hot ex...

Page 5: ...in above the top of chimney 4 Install a blanket plate and the chimney pipe and if used the outside air pipe as shown in Fig 11 5 Attach the DuraVent adaptor a section of pipe and clean out tee make s...

Page 6: ...to Air Intake at the back of stove See Figure 4 for location of Air Intake and attach with Pipe Clamp 4 Route the Metal Pipe into the wall and fix the other end of Metal Pipe into Rodent Guard 5 Attac...

Page 7: ...ch before using vacuum Cleaning 1 Dispose the ash by pulling out the ash drawer Put the ash into air tight metal container and wait for final disposal The metal container or ash shall be placed on a n...

Page 8: ...replace the unit It will have to be returned to us freight prepaid and we will return the repaired or replaced unit to you freight prepaid The company s sole obligation is to repair or replace the un...

Page 9: ...9...

Reviews: