SycoTec 2001 9226 Short Instructions For Use Download Page 6

 
 

EN 

7.2 Digital Outputs 

 

With the "relays outputs" button assign the desired message to the relay. Confirm with "OK". 

 

 

 

7.3 Analog Inputs 

 

With the "analog inputs" button for the duty speed setting select the analog input and set the required 
scaling or select "poti frontpanel". Confirm with "OK". 

 

 

 

7.4 Analog Outputs 

 

With the "analog outputs" button select the desired analog value and set the required scaling. 
Confirm with "OK". 

 

 

Summary of Contents for 2001 9226

Page 1: ...Short Instruction For Use EN HF Inverter e syDrive TV 4504...

Page 2: ...commissioning Content 1 0 Scope of Supply 3 2 0 Connections 3 3 0 Motor 3 4 0 Power Supply 3 5 0 Operation 4 5 1 Assignment of the Spindle Characteristics 4 5 2 Selection of the spindle characteristi...

Page 3: ...or phase V 2 W O Motor phase W 3 PE Protective Conductor 4 PTC I PTC Signal 5 GND I O Ground for PTC 6 4 0 Power Supply The inverter can be connected to either 230V or 115V networks The supply voltage...

Page 4: ...button and the next lower with the STOP button If a characteristic place is not occupied an E stands in front of the character number 5 3 Configuration of the direction of rotation Can only be set up...

Page 5: ...ration of Digital and Analog Inputs and Outputs The digital and analog inputs and outputs are freely configurable with the Windows PC software SFU Terminal http www bmr gmbh de software htm via a D Su...

Page 6: ...with OK 7 3 Analog Inputs With the analog inputs button for the duty speed setting select the analog input and set the required scaling or select poti frontpanel Confirm with OK 7 4 Analog Outputs Wit...

Page 7: ...an be evaluated with the help of the software SFU Terminal At the bar graph display the current load state of the inverter is displayed Errors are displayed as error code in the display If there are m...

Page 8: ...rs free of charge under warranty SycoTec accepts no liability for defects and their consequences which have arisen or could have arisen as a result of natural wear and tear improper handling cleaning...

Page 9: ...EN...