5.0 Operation
5.1 Assignment of the Spindle Characteristics
Assignment
Type of motor spindel
1
4010, 4025, 4026, 4029
2
4033 AC, 4033 AC-ESD
3
4033 AC "2ST-60", 4033 AC-ESD-LS "2ST-60"
4
4033 AC-LN15, 4033 AC-ESD-LN15
5
4015 DC, 4015 DC-G, 4015 DC-M, 4015 DC-R
6
4020 DC
7
4025 DC-T, 4025 DC-T "Sperrluft"
8
4033 DC
5.2 Selection of the spindle characteristics
To select a different characteristic, press the START and STOP button for about 4 seconds simultaniously
The next higher characteristic can be selected with the START button and the next lower with the STOP
button
If a characteristic place is not occupied, an "E" stands in front of the character number
5.3 Configuration of the direction of rotation
Can only be set up before start
Press the STOP button for about 4 seconds
In the setup mode it can be switched with the START / STOP button alternating between Right and Left
The direction of rotation is stored in the inverter, that this selection is maintained even after power off
5.4 Configuration of the rotational speed
Preset manually with the radio knob of the front panel
5.5 Starting and stopping of the frequency inverter
Start with the green START button on the control panel
Stop with the red STOP button on the control panel