5.0 Operation 

 

 

 

5.1 Assignment of the Spindle Characteristics 

 

Assignment 

Type of motor spindel 

4010, 4025, 4026, 4029 

4033 AC, 4033 AC-ESD 

4033 AC "2ST-60", 4033 AC-ESD-LS "2ST-60" 

4033 AC-LN15, 4033 AC-ESD-LN15 

4015 DC, 4015 DC-G, 4015 DC-M, 4015 DC-R 

4020 DC 

4025 DC-T, 4025 DC-T "Sperrluft" 

4033 DC 

 

5.2 Selection of the spindle characteristics 

  To select a different characteristic, press the START and STOP button for about 4 seconds simultaniously 

  The next higher characteristic can be selected with the START button and the next lower with the STOP 

button 

  If a characteristic place is not occupied, an "E" stands in front of the character number 

 

 

 

5.3 Configuration of the direction of rotation 

  Can only be set up before start 

  Press the STOP button for about 4 seconds 

  In the setup mode it can be switched with the START / STOP button alternating between Right and Left 

  The direction of rotation is stored in the inverter, that this selection is maintained even after power off 

 

 

 

5.4 Configuration of the  rotational speed 

  Preset manually with the radio knob of the front panel 

 

5.5 Starting and stopping of the frequency inverter 

  Start with the green START button on the control panel 

  Stop with the red STOP button on the control panel 

 

 

 

Summary of Contents for 2001 9226

Page 1: ...Short Instruction For Use EN HF Inverter e syDrive TV 4504...

Page 2: ...commissioning Content 1 0 Scope of Supply 3 2 0 Connections 3 3 0 Motor 3 4 0 Power Supply 3 5 0 Operation 4 5 1 Assignment of the Spindle Characteristics 4 5 2 Selection of the spindle characteristi...

Page 3: ...or phase V 2 W O Motor phase W 3 PE Protective Conductor 4 PTC I PTC Signal 5 GND I O Ground for PTC 6 4 0 Power Supply The inverter can be connected to either 230V or 115V networks The supply voltage...

Page 4: ...button and the next lower with the STOP button If a characteristic place is not occupied an E stands in front of the character number 5 3 Configuration of the direction of rotation Can only be set up...

Page 5: ...ration of Digital and Analog Inputs and Outputs The digital and analog inputs and outputs are freely configurable with the Windows PC software SFU Terminal http www bmr gmbh de software htm via a D Su...

Page 6: ...with OK 7 3 Analog Inputs With the analog inputs button for the duty speed setting select the analog input and set the required scaling or select poti frontpanel Confirm with OK 7 4 Analog Outputs Wit...

Page 7: ...an be evaluated with the help of the software SFU Terminal At the bar graph display the current load state of the inverter is displayed Errors are displayed as error code in the display If there are m...

Page 8: ...rs free of charge under warranty SycoTec accepts no liability for defects and their consequences which have arisen or could have arisen as a result of natural wear and tear improper handling cleaning...

Page 9: ...EN...

Page 10: ...EN 2 001 9377 2017 03 E DE original...

Reviews: