SycoTec 2001 9226 Short Instructions For Use Download Page 3

 
 

EN 

1.0 Scope of Supply 

 

HF Inverter e

@

syDrive® TV 4504 

Material no. 2.001.9226 

(Drive System SFU 0200/2) 
 
SycoTec 

 Short Instruction For Use 

Material no. 2.001.9377 

HF Inverter e

@

syDrive® TV 4504 

 

BMR 

 CD "Manuals & Software" 

 

Mains cable, length approx. 2 m 

 

15-pole female Submin D connector 
 

2.0 Connections 

 

 

 

3.0 Motor 

 

 

Name 

I/O 

Meaning 

Pin 

Motor phase U 

Motor phase V 

Motor phase W 

PE 

 

Protective Conductor 

PTC 

PTC-Signal 

GND 

I/O 

Ground for PTC 

 

4.0 Power Supply 

 

The inverter can be connected to either 230V or 115V networks. 

 

The supply voltage can be adapted to the relevant mains supply at the bottom of the device using a rotary 
switch. 
In addition, the mains fuse must be replaced accordingly (see table). 

 

Supply voltage 

Fuse 

115 V 

5,0AT 

230 V 

3,15AT 

 

 

 

  Switching the mains voltage may only be carried out by qualified personnel! 

Incorrect setting will cause serious damage to the frequency converter. 

Summary of Contents for 2001 9226

Page 1: ...Short Instruction For Use EN HF Inverter e syDrive TV 4504...

Page 2: ...commissioning Content 1 0 Scope of Supply 3 2 0 Connections 3 3 0 Motor 3 4 0 Power Supply 3 5 0 Operation 4 5 1 Assignment of the Spindle Characteristics 4 5 2 Selection of the spindle characteristi...

Page 3: ...or phase V 2 W O Motor phase W 3 PE Protective Conductor 4 PTC I PTC Signal 5 GND I O Ground for PTC 6 4 0 Power Supply The inverter can be connected to either 230V or 115V networks The supply voltage...

Page 4: ...button and the next lower with the STOP button If a characteristic place is not occupied an E stands in front of the character number 5 3 Configuration of the direction of rotation Can only be set up...

Page 5: ...ration of Digital and Analog Inputs and Outputs The digital and analog inputs and outputs are freely configurable with the Windows PC software SFU Terminal http www bmr gmbh de software htm via a D Su...

Page 6: ...with OK 7 3 Analog Inputs With the analog inputs button for the duty speed setting select the analog input and set the required scaling or select poti frontpanel Confirm with OK 7 4 Analog Outputs Wit...

Page 7: ...an be evaluated with the help of the software SFU Terminal At the bar graph display the current load state of the inverter is displayed Errors are displayed as error code in the display If there are m...

Page 8: ...rs free of charge under warranty SycoTec accepts no liability for defects and their consequences which have arisen or could have arisen as a result of natural wear and tear improper handling cleaning...

Page 9: ...EN...

Page 10: ...EN 2 001 9377 2017 03 E DE original...

Reviews: