9
V2.4
EDID Settings
When using these commands, please note that there are 30 default EDID settings, and 3 User
programmable EDID memories per video input.
For the default EDID memories, the
x
value must be in the range 0 to 29 inclusive (leading zeros
are not required). For the User EDID memories, the value
x
must be one of 30, 31 or 32. The full
list of EDID settings is given on page 4 and the first column indicates the
zz
value for the
SET
INy EDID zz
command stated below.
Command
Description
SET INy EDID zz
Set input
y
EDID to EDID setting
zz
Where
zz
is 00 to 29 one of the 30 built-in EDID settings,
or
30, 31, 32 for the three User defined modes.
SET INx EDID CY OUTy
Copy the EDID from output
y
to input
x
SET INx EDID Uz DATA
XX,
…
Write an EDID data block to input
x
, see below
GET INx EDID
Get the EDID setting for input
x
(if
x
= 0 then the EDID
states for all eight inputs will be returned)
For the
SET INx EDID Uz DATA XX,
…
command, the data block,
{XX,
…}
, must contain
128 or 256 hexadecimal values respectively. Each of the hexadecimal values must be represented
by two ASCII characters and separated by spaces, for example:
SET IN1 EDID U1 DATA 00 FF FF FF FF FF FF 00 4C 2D BE 0B 01 00 00 00
02 18 01 03 80 59 32 78 0A EE 91 A3 54 4C 99 26
0F 50 54 BD EF 80 71 4F 81 C0 81 00 81 80 95 00
A9 C0 B3 00 01 01 04 74 00 30 F2 70 5A 80 B0 58
8A 00 50 1D 74 00 00 1E 02 3A 80 18 71 38 2D 40
58 2C 45 00 50 1D 74 00 00 1E 00 00 00 FD 00 18
4B 0F 87 3C 00 0A 20 20 20 20 20 20 00 00 00 FC
00 53 41 4D 53 55 4E 47 0A 20 20 20 20 20 01 9A
02 03 3A F1 57 61 10 1F 04 13 05 14 20 21 22 5D
5E 5F 60 65 66 62 63 64 07 16 03 12 23 09 07 07
83 01 00 00 E2 00 0F 6E 03 0C 00 40 00 88 1E 21
00 80 01 02 03 04 E3 0F 01 E0 01 1D 80 D0 72 1C
16 20 10 2C 25 80 50 1D 74 00 00 9E 66 21 56 AA
51 00 1E 30 46 8F 33 00 50 1D 74 00 00 1E 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 67
Ideally, the above example would be placed into a text file and then sent to the SY-MSUHD-88
switcher using a serial emulation program. The data given above is only an example and may not
be compatible with the display devices connected to the SY-MSUHD-88 switcher.