SY-HDBT-231
6
V1.0
Input EDID Setup Commands
RS232 Command
Command Details
SET INx EDID y
To use these memory settings, the EDID switch must be set to User 1
EDID Memory (DDUU). The 24 available options are given below.
Set Input x EDID to the built-in EDID y
Input x is: 1-2 = HDMI inputs 1 or 2
EDID y is one of the following (0-23):
0: 1080P_2CH(PCM)
1: 1080P_6CH
2: 1080P_8CH
3: 1080P_3D_2CH(PCM)
4: 1080P_3D_6CH
5: 1080P_3D_8CH
6: 4K30Hz_3D_2CH(PCM)
7: 4K30HZ_3D_6CH
8: 4K30HZ_3D_8CH
9: 4K60Hz(Y420)_3D_2CH(PCM)
10: 4K60Hz(Y420)_3D_6CH
11: 4K60Hz(Y420)_3D_8CH
12: 1080P_2CH(PCM)_HDR
13: 1080P_6CH_HDR
14: 1080P_8CH_HDR
15: 1080P_3D_2CH(PCM)_HDR
16: 1080P_3D_6CH_HDR
17: 1080P_3D_8CH_HDR
18: 4K30Hz_3D_2CH(PCM)_HDR
19: 4K30Hz_3D_6CH_HDR
20: 4K30Hz_3D_8CH_HDR
21: 4K60Hz(Y420)_3D_2CH(PCM)_HDR
22: 4K60Hz(Y420)_3D_6CH_HDR
23: 4K60Hz(Y420)_3D_8CH_HDR
SET INx EDID CY OUTy
Copy Output y EDID To Input x(USER1 BUF) {x[1~2], y[1~4]}
Input x is: 1-2 = HDMI inputs 1 or 2
Output y is: 1 = Local HDMI output
2, 3, 4 = Remote HDBaseT outputs
SET INx EDID U1 DATAz
Write EDID data To USER1 EDID of Input x {x[1~6], z[EDID Data]
Input x = 1 or 2, z must be a valid EDID data block of 256 bytes.
GET INx EDID
Get Input x EDID Index {x[0~2](0 All)}
Input x is: 1-2 = HDMI inputs 1 or 2 0 = Both input EDID index
GET INx EDID y DATA
This command returns the EDID data from input x at EDID index y.
This command will return all 256 bytes of EDID data.
The value x is either 1 or 2, and y is the EDID Index in the range 0 to
12 as given in
GET OUTx EDID DATA
Get Output x EDID Data