background image

We’ve got the power

NEXT GENERATION BATTERY PACKS

JAROCELLS B.V., Waldorpstraat 345, 2521 CJ Den Haag, The Netherlands. [email protected] / www.jarocells.nl

4

JAROCELLS.NL

SAFETY GUIDELINES

General safety

Attention should be paid to all safety instructions in this manual. Maintenance repair work should be carried out by qualifi ed 
personnel. A damaged or abnormal functioning Range Extender should not be used. The Range Extender is intended to use 
for the charging of JAROCELLS LiFePO

4

 batteries (24V or 36V range) by an outboard engine which is connected to a Lead Acid 

starter battery or LiFePO

battery.

Safety during installation

You have to connect the Range Extender to batteries under voltage. Make sure you switch off  all the users of these batteries 
before you make the connections. Prevent shortcut of the wiring during installation and fasten the ring terminals.

Installation and use

Mount the Range Extender close to the starter battery. Make sure the place is free of splashing and dripping water. Keep the 
ventilators 5cm free from surfaces to enable optimal ventilation. Connect the 8mm ring terminals with the starter battery. 
Connect  the  grey  or  red  connector  (24V  is  grey,  36V  is  red)  with  a  contra  connector  (included  in  the  package).  From  this 
connector wires should be connected to the 24V or 36V battery. For a maximum of 2 meters you can use 2,5mm2 wires. For 
wires from 2 to 6m length you have to use 4mm2 or more.
Use the push button to switch the Range Extender in Automatic mode or Off . In Off  mode the Range Extender will not take 
current from your starter circuit. In Automatic mode the Range Extender will look at the State of Charge of your starter 
battery and whether the alternator is running. If the voltage is high enough the Range Extender will draw current from your 
starter circuit and increase the voltage to the right charging voltage for your 24V or 36V battery. As soon as the voltage of 
your starter circuit drops, the Range Extender will stop automatically to keep your starter battery full. As soon as you start 
the engine again, the Range Extender will start simultaneously.
During normal use the circuit breakers will not switch Off . In case a circuit breaker is Off : check the wiring on short circuits.

WARRANTY

>

  The warranty period is two years for the Range Extender.

Warranty provision

>

  The warranty applies to normal use according to recommendations and within specifi cations of the product.

>

  Warranty is only given if the purchase invoice can be submitted.

>

  The warranty does not go beyond repair or replacement of the delivered goods. Consequential damage is expressly stated 

excluded.

>

  In all cases where the warranty conditions are not clear, an attempt will be made to resolve the complaints within reason 

unload. This within the provisions of liability.

Liability

>

  Besides the warranty provisions on the delivered goods, JAROCELLS B.V. will not accept any liability. JAROCELLS B.V. shall 

not be liable for any direct, incidental or consequential damages of any nature, or losses or consequential damages or 
losses or expenses resulting from the use of this product.

>

  The user of the product should take all precautions, required to prevent damage.

>

  In case JAROCELLS B.V. will be held responsible for damage or losses caused by the product, the compensation paid by 

JAROCELLS B.V. will not exceed the payments of the assurance company. When the damage is not covered by the insurance, 
the maximum payment will be equal to the total of the invoice.

>

  Liability and right to warranty is in any case excluded with:

  •  Damage due to external disasters such as lightning strike
  •  Incorrect installation or use
  •  Repairs have been carried out by third parties or changes have been made to the product.

MANUAL 

RANGE EXTENDER

JARO-JRE SERIE

02 / 2022

>

 JARO-JRE 12/24-15A

>

 JARO-JRE 12/36-15A

Summary of Contents for JARO-JRE Series

Page 1: ...JAROCELLS NL MANUAL RANGE EXTENDER JARO JRE SERIE 02 2022 JARO JRE 12 24 15A JARO JRE 12 36 15A ...

Page 2: ...6 4V 26 6V Type of switch Voltage sensitive Relay 120A electronically managed Voltage output 28V 0 2V 42V 0 2V Current output 15A max depending on voltage in 24V or 36V battery Output circuit breaker 30A 30A Type output circuit breaker Thermal magnetic Thermal magnetic Resettable Yes Yes IP rating circuit breakers IP54 IP54 IP rating converter IP67 IP67 IP rating switch IP65 IP65 IP rating ventila...

Page 3: ...cs in parallel JAROCELLS BT125 12 Starter motor The most used combination is a Lead Acid starter battery and a 12v service battery often combined with a VSR Voltage Sensitive Relay so the alternator can charge the service battery too In this combination you can also use te Range Extender to charge your 24V or 36V trolling battery by the alternator When you stop the outboard engine the Range Extend...

Page 4: ...mbination of two LiFePO4 batteries One LiFePO4 battery serves as a starter and service battery The other battery is the 24V or 36V trolling battery By using a Range Extender the alternator will automatically charge all the batteries without the risk that the starter battery is drawn empty When the outboard stops the Range Extender will stop too New feature is that all the connections between the s...

Page 5: ... the right charging voltage for your 24V or 36V battery As soon as the voltage of your starter circuit drops the Range Extender will stop automatically to keep your starter battery full As soon as you start the engine again the Range Extender will start simultaneously During normal use the circuit breakers will not switch Off In case a circuit breaker is Off check the wiring on short circuits WARR...

Page 6: ...We ve got the power NEXT GENERATION BATTERY PACKS JAROCELLS B V Waldorpstraat 345 2521 CJ Den Haag The Netherlands info jarocells nl www jarocells nl ...