We’ve got the power
NEXT GENERATION BATTERY PACKS
JAROCELLS B.V., Waldorpstraat 345, 2521 CJ Den Haag, The Netherlands. [email protected] / www.jarocells.nl
4
JAROCELLS.NL
SAFETY GUIDELINES
General safety
Attention should be paid to all safety instructions in this manual. Maintenance repair work should be carried out by qualifi ed
personnel. A damaged or abnormal functioning Range Extender should not be used. The Range Extender is intended to use
for the charging of JAROCELLS LiFePO
4
batteries (24V or 36V range) by an outboard engine which is connected to a Lead Acid
starter battery or LiFePO
4
battery.
Safety during installation
You have to connect the Range Extender to batteries under voltage. Make sure you switch off all the users of these batteries
before you make the connections. Prevent shortcut of the wiring during installation and fasten the ring terminals.
Installation and use
Mount the Range Extender close to the starter battery. Make sure the place is free of splashing and dripping water. Keep the
ventilators 5cm free from surfaces to enable optimal ventilation. Connect the 8mm ring terminals with the starter battery.
Connect the grey or red connector (24V is grey, 36V is red) with a contra connector (included in the package). From this
connector wires should be connected to the 24V or 36V battery. For a maximum of 2 meters you can use 2,5mm2 wires. For
wires from 2 to 6m length you have to use 4mm2 or more.
Use the push button to switch the Range Extender in Automatic mode or Off . In Off mode the Range Extender will not take
current from your starter circuit. In Automatic mode the Range Extender will look at the State of Charge of your starter
battery and whether the alternator is running. If the voltage is high enough the Range Extender will draw current from your
starter circuit and increase the voltage to the right charging voltage for your 24V or 36V battery. As soon as the voltage of
your starter circuit drops, the Range Extender will stop automatically to keep your starter battery full. As soon as you start
the engine again, the Range Extender will start simultaneously.
During normal use the circuit breakers will not switch Off . In case a circuit breaker is Off : check the wiring on short circuits.
WARRANTY
>
The warranty period is two years for the Range Extender.
Warranty provision
>
The warranty applies to normal use according to recommendations and within specifi cations of the product.
>
Warranty is only given if the purchase invoice can be submitted.
>
The warranty does not go beyond repair or replacement of the delivered goods. Consequential damage is expressly stated
excluded.
>
In all cases where the warranty conditions are not clear, an attempt will be made to resolve the complaints within reason
unload. This within the provisions of liability.
Liability
>
Besides the warranty provisions on the delivered goods, JAROCELLS B.V. will not accept any liability. JAROCELLS B.V. shall
not be liable for any direct, incidental or consequential damages of any nature, or losses or consequential damages or
losses or expenses resulting from the use of this product.
>
The user of the product should take all precautions, required to prevent damage.
>
In case JAROCELLS B.V. will be held responsible for damage or losses caused by the product, the compensation paid by
JAROCELLS B.V. will not exceed the payments of the assurance company. When the damage is not covered by the insurance,
the maximum payment will be equal to the total of the invoice.
>
Liability and right to warranty is in any case excluded with:
• Damage due to external disasters such as lightning strike
• Incorrect installation or use
• Repairs have been carried out by third parties or changes have been made to the product.