SWP Stealth-XG 6044 Operator'S Manual Download Page 3

2

1. INTRODUCTION

Respirator system is intended to be used to provide protection when the user working in
the contamination environment. The equipment is able to filter the contaminate air via
the filter build in to the blower and then supply fresh air from breathing tube to the
welding faceshield, so that the user can continually working in contamination
environment. It is a combined face and breathing protection device for increased safety
and comfort during welding. Please read these instructions carefully before unpacking.
For proper use, see user instructions or contact manufacturers for help.

2. APPROVALS

The system complies with the requirements of

PPE Regulation 2016/425 and

European Standard EN 12941: 1998+A2:2008 class TH3 P R S L . The respirator
system is designed to provide a supply of filtered air via a breathing tube to a welding
headpiece. The equipment can be used in environment that requires a class TH3P
breathing protection device. It protects against articulate contamination.
All components used in respirator system must be manufacturer approved parts, and
must be used in accordance with the instructions in this manual.

1. The approval is not valid if the product is incorrectly used together

with non-approved parts or components.

2. Only the particle filter and pre-filter can be used together with this

system. Filters fromother manufacturers should under no circumstances

be used.

PAPR  PRECAUTIONS

Notified Body: Vyzkumny ustav bezpecnosti prace, v. v. i., Jeruzalémská 1283/9, 11
0 00 Praha 1, Czech Republic (Notified body number 1024)

3

2

3.WARNING AND LIMITATIONS TO USE

Before each use, inspect the respirator system for damage and verify it operates
properly. Before using the respirator system, test air flow to verify it is providing an
adequate volume of air.
Always wear the respirator system and do not remove the head top or turn off the air
filter unit until outside the contaminated area, otherwise, there is a risk of high
concentration of CO

2

and oxygen level in the head top will fall, thus little or no protection

is given.
If you are not sure about the concentration of pollution, or about equipment performance,
ask the industrial safety engineer.

The manufacturer is not responsible for injury due to the following

incorrect use or incorrect choice of equipment.

Warning:

This respirator devices should be used with well trained person and qualified person
only.
Before using the devices ensure you have understood that at very high work rates the
pressure in the device may become negative at peak inhalation flow.
Before and during using the devices, attention shall be drawn to possible incorrect use
and, where appropriate, the possibility of looped hoses and/or cables becoming caught
up.
Before or during using the devices if the devices in the power-off state little or no
respirator protection is to be expected, and that this is considered to be an abnormal
situation.
Please leave the work place and remove the headgear, when the devices in the
power-off state a rapid build-up of carbon dioxide and depletion of oxygen within the
hood may occur.
The filters shall only be fitted to the turbo unit and not directly to the helmet/hood.
The user should not confuse the markings on a filter relating to any standard other than
EN 12941 with the classification of this device when used with this filter.

DO NOT

use SparX Air with the blower unit switched off.

Summary of Contents for Stealth-XG 6044

Page 1: ...refully before using this unit Failure to comply with the instructions may void your warranty and adversely affect your health and safety Weld Grind Helmet Digi Air PAPR System Part No 6044 6044BT OPE...

Page 2: ...6 425 and European Standard EN 12941 1998 A2 2008 class TH3 P R S L The respirator system is designed to provide a supply of filtered air via a breathing tube to a welding headpiece The equipment can...

Page 3: ...ualified person only Before using the devices ensure you have understood that at very high work rates the pressure in the device may become negative at peak inhalation flow Before and during using the...

Page 4: ...plied as in figure 1 Check that the apparatus is complete undamaged and correctly assembled Any damaged or defective parts must be replaced before use FIGURE 1 The package must include 1 The helmet wi...

Page 5: ...The filter cover is released 3 Remove the used filter by lifting it out from the filter cover 4 5 Remove the pre filter 6 Clean the spark arrestor if necessary If the filter is wet or heavily loaded...

Page 6: ...not be used for anything else than it was designed for Do not charge the battery in a potentially explosive area The charger must only be used indoors The charger regulates the charge automatically o...

Page 7: ...witches on 5 Disconnect the charger from the mains do not keep the charger plugged to the mains if it s not in use 4 3 Installing the respirator system on the belt 1 Remove the belt s release buckle 2...

Page 8: ...ist it clockwise to lock its position 2 Connect the other end of the tube to the headgear in the same way 1 Check that the respiratory tube is strongly connected If the tube is broken replace it All c...

Page 9: ...the tip of the tube 3 Press the ON button and maintain the tube in a vertical position at eyes height 4 The air flow is sufficient if the marble reaches the minimum flow level O 1 The airflow must be...

Page 10: ...he alarm does not work please repair or change respirator system 5 3 Fitting Make sure the face seal is positioned properly otherwise you can t get sufficient sealing needed to offer the correct prote...

Page 11: ...th XG working condition FIGURE 3 FIGURE 3 Part 1 shows the data of current air flow Part 2 shows the level of the airflow Part 3 shows the filter condition Part 4 shows the battery Part 5 shows the te...

Page 12: ...ress the ON button once again the air flow reverts to level 1 170L min 1 The respirator system will turn off the turbo unit if long press the OFF button more than 3 seconds 2 The respirator system wil...

Page 13: ...nfectant and water in a ratio of 1 99 Wipe the surface of the equipment with a clean lint free tissue or cloth that takes the solvent Then wipe the surface of the equipment with another clean lint fre...

Page 14: ...be blocked Remove obstruction change the filter Clean tube blinks alarm sounds Battery high temperature Stop working and rest No air flow no alarm 1 No power 2 Battery contact damaged Charge the batte...

Page 15: ...31 5 55 Storage temperature 14 to 131 10 55 Battery Type Standard Battery Rechargeable Li ION 4400mAh Optional Heavy Duty Battery Rechargeable Li ION 6800mAh Expected Battery Operation Time Standard b...

Page 16: ...type P Particle filter R Reusable type of particle filters and SL reflects the filter has been tested against particles of liquid and solid matter Warning indication This Stealth XG PAPR has sound an...

Page 17: ...om the date of purchase The company undertakes to exchange or repair without charge any part found to be defective within this period alternatively and at its discretion The Company may replace This g...

Page 18: ...A T T AUTO DARKENING HELMET 18 Specification of ADF...

Page 19: ...Battery Life Battery Life T T L L V T T 104 5 Remote 19 MODEL STEALTH XG...

Page 20: ...20...

Page 21: ...21...

Page 22: ...22...

Page 23: ...23...

Page 24: ...F 149 F 13 Inside PC lens 105 8 x 65 8 x 1 mm 14 Outside PC lens 110 x 90 x 1mm 15 Standards CE EN379 ANSI Z87 1 CSA Z94 3 AS NZS 16 Warranty 2 years BEFORE USE Check for light tightness and check th...

Page 25: ...increased Or Anticlock wise rotate the button on the ADF Shade number will be reduced If the Shade is in the range of 9 13 clock wise rotate the button on ADF Shade number wi l l be increased Or Antic...

Page 26: ...rays after welding Delay time can be adjusted by rotate the DELAY button on ADF Position 4 Clockwise rotate the button on the ADF Delay time will be increased Or anticlockwise rotate the button on th...

Page 27: ...REPLACE INNER VISOR HEADGEAR ADJUSTMENTS REPLACE OUTER PROTECTION LENS 27...

Page 28: ...28...

Page 29: ...m 6 6044 06 XA 1131 I ADF SET 7 6044 07 XA 1131 I ADF 8 6044 08 ADF Frame 9 3021 Inner protection lens 105 8x65 8x1mm 10 6044 10 ADF Lock 11 6044 11 Inner lens SG PC SN 1 curve 12 6044 12 Silder lock...

Page 30: ...30...

Page 31: ...3044BLT Waist Belt PE 27 3044HARN Shoulder Harness 28 4044BAG Carrying Bag 29 6044 29 Breathing Tube flexible 0 6m 30 6044 30 Anti fire Cloth of Breathing Tube 1 48m 31 3044BAT Standard Battery 4400m...

Page 32: ...tre Unit 1 Withins Road Haydock Industrial Estate Haydock WA11 9UD UK T 44 0 1942 719930 Head Office Unit 1A Farringdon Industrial Centre Farringdon Nr Alton Hampshire GU34 3DD UK T 44 0 1420 588180 w...

Reviews: