6.2 Operation
Switch the device on by pressing the ON button once.
Press the ON button once again, the air flow is at level 1 (~170L/min).
Press the ON button once again, the air flow is at level 2 (~200L/min).
Press the ON button once again, the air flow is at level 3 (~230L/min).
Press the ON button once again, the air flow reverts to level 1 (~170L/min).
1. The respirator system will turn off the turbo unit if long press the OFF
button more than 3 seconds.
2. The respirator system will cut off the entire circuit and switch to sleep mode if
the turbo unit has turned off for more than 30 minutes. Pressing the ON button
can activate the system.
3. The respirator system must be operated in the temperature range of
-5
℃
to +55
℃
and relative humidity less than 90%RH.
13
14
7
. MAINTANCE & STORAGE
Inspect the equipment daily and always check it if any sign of malfunction occurs.
7.1 Maintenance
The respirator system unit must be checked regularly and must be changed if it is
damaged and cause leakage.
The filter must be changed if it is broken, or it is blocked and does not give enough
airflow.
The breathing tube must be changed if it is broken or has crevasse.
The battery must be charged when the low battery alarm rings.
Use a soft cloth to wipe the external surfaces. Don’t use water!
Disinfect the equipment with disinfectant not having any adverse effect on the PPE or
the user. Dettol disinfectant is recommended. Dilute the disinfectant and water in a ratio
of 1:99. Wipe the surface of the equipment with a clean lint-free tissue or cloth that takes
the solvent. Then wipe the surface of the equipment with another clean lint-free tissue or
cloth that takes water.
The filter should be replaced together with the pre-filter.
7.2 Storage
The respirator system must be stored in a dry, clean area, in the temperature range of
-10
℃
to +55
℃
and relative humidity less than 90%RH.
If the equipment is stored at temperature below 0
℃
, the battery must be allowed to
warm up to achieve full battery capacity. The equipment must be protected from dust,
particles and other contamination.
If the equipment is not used for a long time, the battery should be fully charged, removed
from the respirator system unit and stored separately.
Transport the equipment with original packaging box and away from direct sunlight.
Summary of Contents for Stealth-XG 6044
Page 18: ...A T T AUTO DARKENING HELMET 18 Specification of ADF...
Page 19: ...Battery Life Battery Life T T L L V T T 104 5 Remote 19 MODEL STEALTH XG...
Page 20: ...20...
Page 21: ...21...
Page 22: ...22...
Page 23: ...23...
Page 27: ...REPLACE INNER VISOR HEADGEAR ADJUSTMENTS REPLACE OUTER PROTECTION LENS 27...
Page 28: ...28...
Page 30: ...30...