Learn RC
This menu is to train the transmitter to the ECU.
Max – Throttle up, trim up
Idle – Throttle down, trim up
Min – Throttle down, trim down
FailSafeTime – set fail safe time in seconds
[BUS] Throttle cha – setup throttle channel if use BUS Mode input
[BUS] Switchcha – setup switch channel if use BUS Mode input and
switch startup function,if turn on this function ,ppm input will
invalid, need use BUS mode for input
TelemetryMode – set telemetry mode 1/1 for single engine mode
Starter
Eject Time – sets the time for a reverse voltage pulse to disengage
the starter.
Eject Voltage – sets the eject voltage in order disengage the clutch
on startup
Run Voltage – Sets the voltage for the starter during startup
RPM Stable – rpm adjust rate of starter
Engine Cooling
Sets the cooling rpm after shut down or when starter is manually
run using test functions.
*Please note that following a failsafe failure or flameout that the
motor will not automatically enter a cool down sequence. This is
because the ECU has no way of knowing the status of the motor
whether flame out, crash or other.