background image

Start Up Screen

PumpVoltage - Set pump voltage Typical value is 0.4-0.5v
RPM StartUp Ramp – Set ramp profile starter , This parameter
adjusts the speed of the starter increase during the “Preheat to RPM
Off Starter” phase. Higher values mean a faster rpm increase.
Increase this value if the engine too hot duing preheat to rpm off
starter , and decrease it if flame out duing preheat to rpm of starter.
Pump StartUp Ramp - This parameter adjusts the speed of the fuel
increase during the “Fuel ramp” phase. Higher values mean a faster
fuel flow increase. Increase this value if the engine takes too long to
arrive to idle, and decrease it if the starts are too hot, with the
engine overshooting the idle speed.
GlowPlug – Set Glow Plug Voltage.
GasValve – Set the values of time of the gas fuel valve is open at
beginning of the ignition phase.
Ignition RPM – Set the RPM where ignition phase commences
Preheat RPM – Set the RPM value for preheat phase to begin.
RPM Off Starter – Set the RPM where the starter motor will
disengage.

Running Display

RPM Acceleration/Deceleeation Curve/Delay time
Higher values mean a faster rpm increase/decrease rate. Adjust
according to weather, Altitude (ASL) or other conditions which
require adjustments to delay time. It is best to select a value that is
lower than a setting that yields the fastest possible response time in
order to avoid a flame out.
Raise value to decrease response time, Lower value to increase
response time
Max RPM – Set maximum RPM
Idle RPM – set idle RPM
Min RPM – set stop RPM , if motor RPM falls below this setting,
motor will shutdown.
MaxTemp - Set maximum running temp.If motor exceeds this value,
ECU will automatically limit fuel in order to reduce the temp.
LowVolt – set low volt warning
Restart - Can be set “valid” for enable or

invalid” disabled, flame

out automatically restart or not.
Restart power pump – set power to pump on restart. Normal range
from 0.3 – 0.7 Volt
PumpLimit – This value is used to set the limit to the pump to a
reasonable limit and is based on observation of actual running
values. Set this value to 20% higher than what is observed on the
main screen. This prevents excess pump pressure.
IdlePumpStab – set pump stable delay on idle rpm, normaly SW60B
tubine set 5-8, SW120-210 set 3-5

Summary of Contents for SW Brushless Series

Page 1: ...SWIWIN Turbines SW Brushless Series Kero Start Full Autostart with Auto Restart Operations Manual ...

Page 2: ...njury to the user or bystanders Our responsibility is explicitly limited to the motor and to the internal workings and ancillary supplies offered with the turbine SWIWIN USA advises ALL users novice or pro to test their motors in a test stand before mounting them in a plane The reason for this is to familiarize yourself with SWIWIN motor operation and to ensure reliable operation before mounting t...

Page 3: ...r a fire extinguisher and it was not where it needed to be and or the extinguisher was not operational Failsafe Please read carefully the notes on setting the failsafe on your radio to of interference or loss of signal Ear Protection Turbines produce excessive dB levels of noise when running the engine Burns Exhaust gases are very hot up to 1000 C and can cause burns to skin or damage to objects c...

Page 4: ...such repair or replacement is required and is due to a malfunction during normal usage 2 SWIWIN will cover labor charges associated with any warranty repair 3 SWIWIN warranty coverage is limited to replacement of parts and repair of the unit and does not apply to any other losses or damages consequential or inconsequential to the failure 4 Buyer is required to register the motor with SWIWIN at the...

Page 5: ...one number email address etc Please also include a photo copy of the original sales receipt 8 Owner agrees to cover charges for all parts and or labor charges not covered by this warranty 9 In the event that a turbine is returned and it is later determined that the engine has failed due to issues that are not covered under the warranty see above conditions the owner will be provided with a repair ...

Page 6: ...ry cable to ECU port labeled 3S LIPO BATT 3 Connect the pump to the deans connector on the battery cable 4 Connect the GSU to the ECU port labeled GSU PC 5 Connect the engine cable to the ECU port labeled ENGINE Engine cable Brushless pump and Traditional pump Throttle line Battery power cable Motor Setup Please refer to Figure 3 Motor Setup above ...

Page 7: ...med Failure to conduct this exercise will cause the motor not to run Note Some users report running the pump for a few minutes with fuel circulating to break in the pump before running the engine for the first time 5 Turn on power to the Radio Controller Note an audible sync signal when the radio is powered up This lets the user know that the motor is online with connection to the radio 6 Raise th...

Page 8: ...in continuously until the motor is cooled Previous firmware releases spun the motor intermittently to save the life of the motor 4 Turn off the fuel 5 Turn off power to the controller 6 Turn off power to your radio ECU The SWIWIN ECU was designed from the ground up and is based on 32 bit microprocessor functionality and designed specifically for SWIWIN Turbines The ECU offers the following benefit...

Page 9: ...PM 0 100 Temp 0 1000 Celsius Pump output measured in volts ex 4500 1000 4 5 volts RC throttle position from 0 100 Large font Running Screen Press C to toggle between large screen and normal Main menu initial screen From the initial screen press OK key click C to toggle back to boot screen StartUp enter startup menu Running enter Running menu Adjust RC Train Radio to ECU Starter set starter power C...

Page 10: ...g Display RPM Acceleration Deceleeation Curve Delay time Higher values mean a faster rpm increase decrease rate Adjust according to weather Altitude ASL or other conditions which require adjustments to delay time It is best to select a value that is lower than a setting that yields the fastest possible response time in order to avoid a flame out Raise value to decrease response time Lower value to...

Page 11: ...try mode 1 1 for single engine mode Starter Eject Time sets the time for a reverse voltage pulse to disengage the starter Eject Voltage sets the eject voltage in order disengage the clutch on startup Run Voltage Sets the voltage for the starter during startup RPM Stable rpm adjust rate of starter Engine Cooling Sets the cooling rpm after shut down or when starter is manually run using test functio...

Page 12: ...increase pump speed Pump increases gradually Test pump initiates fuel solenoids simultaneously Be careful not to flood the engine Test Fuel Valve press OK to activate fuel valve Test Gas Valve press OK to activate Gas Valve this controls fuel to the glow plug Test Glow Plug press OK to activate Glow Plug circuit A glow can be seen from the rear of the motor Test Starter Press OK to activate starte...

Page 13: ...Spec ...

Page 14: ... 144 000RPM 310g min 112 500RPM 325g min 115 200RPM 351g min 99 000RPM 380g min 10 3500RPM Fuel kero or diesel kero or diesel kero or diesel kero or diesel kero or diesel Lubrication 5 kero 3 diesel 5 kero 3 diesel 5 kero 3 diesel 5 kero 3 diesel 5 kero 3 diesel Maintenance Interval 25Hours 25Hours 25Hours 25Hours 25Hours Service www sw jet com Service sale sw jet qq com Name Thomas Chiang USA Ser...

Reviews: