background image

Copyrights by 

 

Ausgabe 0.4    

Swissphone Telecom 

 

30.11.2005 

Fälmisstr. 21 CH-8833 Samstagern 

Art. Nr. 0343130 

Seite 6/10 

 

 

Loud alert  

Incoming calls are signalled simultaneously with a call signal and a vibration. In 
addition, the LED in the upper left corner starts flashing. Following these signals, you 
will hear the spoken announcement via the loudspeaker (not applicable to the "Tone" 
model). 

 

Minibeep 

Incoming calls are first indicated by the vibrator, and then with short beep tones. The 
LED in the upper left corner also flashes. Following these signals, you will hear the 
spoken announcement (not applicable to the "Tone" model). 

 

Silent alert  

Incoming calls are signalled only by the vibrator. There is no acoustic alarm, and no 
spoken announcement is heard. 

 

Monitor  

(Only applicable to the "Voice" and "Memo" models) 

In this operational mode, you can hear everything that is spoken over the set radio 
channel. Calls addressed to you will be signalled "acoustically". If you wish to switch off 
the continuous monitoring / listening operation, select one of the acoustic symbols with 
key (1), and confirm this with key (2). 

 

((i))

 

Remark

 

Pagers with the voice memory (Memo) will always record the spoken message when the 
programming of the voice memory has been assigned to the appropriate address and the 
alarm type has been set to "Voice" or "Tone & Voice" status. In monitor mode, a spoken 
message will only be recorded if the proper address has been activated. Via programming, 
the voice memory can be assigned either a fixed or dynamic mode. The total recording time 
can be set to 8x30, 6x40, 4x60, 3x80 or 2x120 sec. Please find more information in the 
Programming Manual. 

 

Volume  

(only applicable to "Voice" and "Memo" models) 

The volume for voice messages can be set to one of 4 levels. The volume of the call 

signal is not affected by this parameter. With key (1), select the volume symbol. 
Using key (2), you can now select the desired levels 1, 2, 3 or 4, which you can then 
acknowledge with key (1). Level 1 is the quietest and Level 4 the loudest. Level 3 

corresponds to the nominal volume. 
 

New message 

Incoming calls can be signalled via the loudspeaker and the vibrator together, 

depending on the operational mode. In addition to the complete 
alerting, you can also listen directly to the incoming voice message (not 
applicable to the "Tone" model). Depending on the transmission type, 
several seconds may elapse between the wake tone and the voice 
message. During this period, no commands can be issued to the 
receiver. After the voice message plays, the LED (light display) in the 

upper left corner also blinks. 
In the display, you will see the names, the address (only "Voice" and "Memo") and an 
arrow indicates one of the 4 display fields. At a glance, you see which alarm address 
was triggered. 
If an occupied address or call is not acknowledged, then a reminder call will 
periodically be issued (at pre-set time intervals). This can either be indicated 

Summary of Contents for re629

Page 1: ...5 Loud alert 6 Minibeep 6 Silent alert 6 Monitor Only to models Voice and Memo 6 Volume Only to models Voice and Memo 6 New message 6 Address display Only to models Voice and Memo 7 Call retrieval 7...

Page 2: ...e this product in hazardous atmosphere or explosion risk areas Do not open device or remove labels This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditio...

Page 3: ...he supply source with the negative pole leading so that the spiral spring is slightly compressed and then simply lay the battery into the battery compartment 3 Replace the battery cover and push it in...

Page 4: ...simple ergonomic and is designed for a high level of operational security The keys are located in the upper left and right corners of the unit The left hand key is SELECT 1 and it allows you to move...

Page 5: ...RE629 Voice and Memo models RE629 Tone and Eco models Minibeep Loud alert Silent alert Scanner Monitor Call addresses 4 digit address display Battery capacity display Clock functions Field strength a...

Page 6: ...a spoken message will only be recorded if the proper address has been activated Via programming the voice memory can be assigned either a fixed or dynamic mode The total recording time can be set to 8...

Page 7: ...ess the EXECUTE key 2 and the address arrow of the last message received will begin to flash for about 3 seconds Simultaneously the LED display in the upper left corner shows the appropriate address p...

Page 8: ...minutes have passed the time will only be displayed in hours and minutes The arrow and LED continue to flash The time is not displayed anymore once the counter overflows when min 12 hours only the LE...

Page 9: ...ter a new energy source is inserted the pager always detects whether it is a rechargeable battery or a dry cell battery This switch on procedure with self test is only possible when the voltage of the...

Page 10: ...ce Port For the connection of various accessory devices e g battery charer programming kit Accessory devices LG Standard charging unit Economical intelligent charging unit ALG Standard charging unit E...

Reviews:

Related manuals for re629