background image

9

Aton CL108 / Swisscom EN / A31008-M2005-F151-1-2X19 / main.fm / 23.07.2008

The following functions can be selected with 

u

:

Calling back a caller from the calls list

f

 

¢

 CallsList 01+02 

¢

 OK 

¢

 

u

 

(select entry)

 

¢

 

c

Assigning key 1 for fast access to the 

network mailbox

Simply press and 

hold

 key 

1

 on the handset and 

you will be connected directly to the network mail-

box.
See Menu tree 

¢

 p. 13.

Locating a handset ("paging")

You can locate your handset using the base station. 

Briefly

 press the registration/paging key on the 

base station (

¢

 p. 1).

All handsets will ring simultaneously ("pag-

ing"), even if the ringer tones are deactivated.

End paging:

 

briefly

 press the register/paging key 

on the base station (

¢

 p. 1) or the talk key 

c

 on 

a handset.

Registering handsets

You can register up to four handsets on your base 

station.

For automatic registration of handsets to 

Aton CL108, see 

¢

 p. 5.

Manual registration of handsets to Aton CL108

1. On the handset: 

MENU 

¢

 Settings 

¢

 OK 

¢

 Handset 

¢

 OK 

¢

 Register HS 

¢

 

Enter the sys-

tem PIN of the base station (default is 0000)

 

¢

 OK

 

Registering flashes in the display

.

2. On the base station: 

within 

60 sec.

 of entering 

the system PIN, press and hold the registration/

paging key (

¢

 p. 1) (min. 3 sec.). 

Registration takes approx. 1 minute.

De-registering handsets

Handsets can only be de-registered by resetting 

the base station to its default settings. 

This will 

also reset every other setting

 

¢

 p. 10

.

If you have 

only

 registered handsets for other GAP-

compatible devices, these can only be de-regis-

tered with a 

hardware reset

 

¢

 p. 10.

Using several handsets

Making internal calls

Internal calls are free calls to other handsets that 

are registered to the same base station. 
To make a call to other handsets, press

INT

 

¢

 

~

 (1...4, enter internal number of the 

handset) 

¢

 

OK

, the handset is called 

or

INT

 

¢

 star key 

P

 

¢

 

OK

, all handsets are 

called.

When a participant answers you can speak to 

them. To end the call, press 

a

.

Internal consultation call/connecting 

a call

You are in conversation with an 

external

 partici-

pant. Press the 

INT

 key and call one or all handsets. 

The external participant hears the hold music. 

Before

 the internal participant has answered, 

press the end call key 

a

; the call is diverted to 

the participant who answers the call.

After

 the internal participant has answered, 

you can talk to him. Press the end call key 

a

the call is diverted, 

or

 press the display key  ; 

you are reconnected to the external participant.

Listening in to an external call

You are conducting an external call. An internal 

participant can listen in on this call and take part in 

the conversation (conference). 

Precondition:

 The 

Listening in 

function must be 

activated. 

Activating/deactivating listening in

MENU 

¢

 Settings 

¢

 OK 

¢

 Base 

¢

 OK

 

 

¢

 Listening in 

¢

 OK 

(

 

= on) 

Internal listening in (conference)

You want to listen in to an existing external call.
Briefly press and 

hold

 the 

c

 key. You can listen in 

to the call. All participants hear a signal tone. 

To end

: press the end call key 

a

. All participants 

hear a signal tone.
If the 

first

 internal participant presses the end call 

key 

a

, the handset that has "listened in" remains 

connected to the external participant.

Delete Entry

Delete current entry.

Copy to Dir.

Copy an entry to the directory.

Date/Time

Call date and time (if set).

Status

New Call:

 new missed call. 

 

Old Call: 

entry already read. 

 

Answ.:

 call taken.

Delete List

Warning!

 All 

old and new

 

entries will be deleted.

Please note:
Each

 additional handset must be registered on 

the base station in order for it to work properly! 

Summary of Contents for Aton CL108

Page 1: ...Registration Paging key p 9 11 2 3 5 7 4 6 9 13 1 Handset 12 14 8 10 Where to find it all First steps p 3 Making calls p 7 Using the directory and lists p 7 Registering handsets p 9 Using several han...

Page 2: ...to your hearing The handset may cause an unpleasant hum ming noise in hearing aids Do not install the phone in a bathroom or shower room The handset and base station are not splashproof Do not use you...

Page 3: ...nt varnishes and polishes used on today s furnishings the occurrence of marks on the surfaces cannot be completely ruled out Please note Never expose the telephone to the influence of heat sources dir...

Page 4: ...ld result in significant health risks and personal injury For example the batteries could explode The phone could also malfunction or be damaged as a result of using batteries that are not of the rec...

Page 5: ...errupts the automatic registration If automatic registration does not work the handset will have to be registered manually p 9 Only place the handset in the base station or charging cradle that is int...

Page 6: ...it will automatically activate Your phone is now ready for use If you have any questions about using your phone please read the tips on troubleshooting Faults and self help with troubleshooting p 12...

Page 7: ...king external calls Your caller can no longer hear you Press the Microphone off key during the call to activate deactivate the function Handsfree Activating while dialling Enter the number and press t...

Page 8: ...the f key all the lists are dis played If only one list contains new messages this will be opened automatically Calls list Precondition CLIP p 7 Depending on the type of list set the calls list con t...

Page 9: ...the same base station To make a call to other handsets press INT 1 4 enter internal number of the handset OK the handset is called or INT star key P OK all handsets are called When a participant answe...

Page 10: ...K Cancel the reset with a Restoring the base station to the factory settings When restoring factory settings All handsets are de registered Individual settings are reset All lists are deleted The syst...

Page 11: ...7 800 ms enter number OK Changing pause after line seizure You can set the length of the pause inserted between pressing the talk key c and sending the phone number MENU 4 I O 1 O The number for the c...

Page 12: ...red consumed material which is not covered by the warranty service Faulty batteries are not replaced free of charge This applies to rented as well as purchased devices Help If you have any general que...

Page 13: ...Handset Volume 2 1 1 Earpiece Can be set to one of 3 levels 2 1 2 Speaker Can be set to one of 5 levels 2 2 Ringer Volume 5 levels crescendo available 2 3 Ringer Melody 2 3 1 External Calls 10 ringer...

Page 14: ...egister HS Manually register the handset p 9 4 2 4 Reset Handset Reset the handset p 10 4 3 Base 4 3 2 Call list type 4 3 2 1 Missed Calls p 8 4 3 2 2 All Calls p 8 4 3 3 System PIN Change system PIN...

Reviews: