background image

 

 

 

Caution and safety precautions 

 

 

Never use any  other charger than the supplied or a  type approved by Swiss Timing. This could destroy the 
battery, cause damage to unit, and possible cause personal injury due to fire or/and electrical shock. 

 

Never bypass a power cord ground lead by breaking off the ground pin, or by using inappropriate extension 
cords or adapters. 

 

Never plug a power cord into the AC power source until you have made sure that all installation, cabling and 
power levels, are proper, and that the applicable procedures in this manual have been followed.  

 

Protect the equipment against splashing, rain and excessive sun rays.  

 

Never use the device if it is damaged or insecure.  

 

Verify the selection of the power distribution. 

 

Verify that the voltage quoted on the rating plate is the same as your voltage. Connect the appliance only to 
power sockets with protective earth. The use of incorrect connection voids warranty.  

 

This program may be modified at any time without prior notification. 

 

Do not open the case; there is nothing that needs servicing inside it. Nevertheless, if the case must be opened, 
you must call for some qualified personnel. The power supply cable must be disconnected before opening the 
case. 

 

During the transport of all Swiss Timing equipment delivered with a reusable carry case, the said case should 
be used at all times. This is imperative to limit the damage, such as shocks or vibration that can be caused to 
the units during transport. 

 

The same cases should also be used when returning equipment to Swiss Timing for repair. Swiss Timing reserves 
the right to refuse all guarantees if this condition is not fulfilled.  

 

If the installation includes a horn, be sure to maintain a sufficient security distance from the public. 

 
 
 
 
 
 
 

Documentation Updates 
Swiss Timing SA reserves the right to make improvements in the products described in this documentation at any time 
without prior notice. Furthermore, Swiss Timing SA reserves the right to revise this documentation in its content at any 
time and without any obligation to notify any person or organization of such revision.   
 
Disclaimer 
The information provided in this documentation has been obtained from sources believed to be reliable, accurate and 
current.  However,  Swiss  Timing  SA  makes  no  representation  or  warranty,  express  or  implied,  with  respect,  but  not 
limited to, the completeness, accuracy, correctness and actuality of the content of this documentation. Swiss Timing SA 
specifically disclaims any implied warranty of merchantability, quality and/or fitness for any particular  purpose. Swiss 
Timing SA shall not be liable for errors contained in this documentation or for incidental or consequential damages in 
connection with the supply, performance or use of this documentation. 
 
Environment 

This symbol indicates that this product should not be disposed with household waste. It has to be returned 
to a local authorized collection system. By following this procedure you will contribute to the protection of 
the environment and human health. The recycling of the materials will help to conserve natural resources. 
 

Copyright  
© Swiss Timing SA  
All rights reserved.  
This documentation may not, as a whole or in part, be copied, translated, reproduced, transmitted or reduced and/or 
stored to any electronic medium or machine-readable form without the prior written consent of Swiss Timing SA 

 

Summary of Contents for ASI

Page 1: ...ss Timing LTD Phone 41 32 488 36 11 P O Box 138 Rue de l Envers 1 info swisstiming com CH 2606 Corgémont Switzerland www swisstiming com ATHLETICS SWITCHER INDOOR USER S MANUAL 3373 502 02 l Version 1 0 l ...

Page 2: ...right to refuse all guarantees if this condition is not fulfilled If the installation includes a horn be sure to maintain a sufficient security distance from the public Documentation Updates Swiss Timing SA reserves the right to make improvements in the products described in this documentation at any time without prior notice Furthermore Swiss Timing SA reserves the right to revise this documentat...

Page 3: ...Single power supply and external battery 4 3 1 4 Double external batteries 4 3 2 Cameras connections 5 3 2 1 Cameras PRY 60M SDY 60M PRY 200M TimingRoom SDY 200M TimingRoom 5 3 2 2 Cameras PRY 60M SDY 60M PRY 200M Track SDY 200M Track 6 3 2 3 Cameras PRY 60M SDY 60M PRY 200M Track SDY 200M TimingRoom 6 3 2 4 Cameras PRY 60M SDY 60M PRY 200M Track SDY 200M Track Timer 7 3 3 Rear panel description 8...

Page 4: ... Version 1 0 5 1 Install drivers 11 6 CONNECTORS DESCRIPTION 13 7 TECHNICAL SPECIFICATIONS 14 7 1 Mechanical characteristics 14 7 2 Electrical characteristics 14 8 APPENDICE 15 8 1 Index figures 15 8 2 Version history 15 ...

Page 5: ......

Page 6: ......

Page 7: ...se start system timing scoreboards finish photocells at 60m and 200m intermediate photocells at 1500m headset additional RS422 output Power supply 10 15VDC external PSU 110 240 VAC 15VDC Possibility to connect 4 OSV cameras Data output can be switched between PRY and SDY cameras 60M and 200M Wind speed and false start ASC data dispatched between PRY and SDY cameras 60M and 200M OSV ready monitorin...

Page 8: ...CONNECTIONS 2 1 Connections overview Only one Start StartTime or False start ASC can be connected on the track All unused start systems must be disconnected You may only reconnect start system if necessary 2 2 Front view 2 3 Rear View ...

Page 9: ...ASI Athletics Switcher Indoor Version 1 0 3373 502 02 Page 3 2 4 Distribution of RS422 data ASC3 False start Scoreboard 2 5 Distribution of START FINISH contacts START FINISH ...

Page 10: ... There are several possible cabling solutions and you will find some examples below 3 1 Timing Room connections 3 1 1 Single power supply 3 1 2 Double power supply 3 1 3 Single power supply and external battery 3 1 4 Double external batteries ...

Page 11: ...m 2 on the track The selection of the PRY 200M and SDY 200M switch is valid for Track and Timing room cameras If CELL is selected both PRY or SDY cameras will record when Finish photocell is activated If MAN is selected both PRY or SDY cameras will record when pushbutton is activated 3 2 1 Cameras PRY 60M SDY 60M PRY 200M TimingRoom SDY 200M TimingRoom ...

Page 12: ...SDY 60M PRY 200M Track SDY 200M TimingRoom An additional timer can be connected to the START and FINISH contacts trough the 200M PRY or SDY camera connector A specific cable is needed according to the timer model In this configuration select the INFIELD switch in position CELL Do not use pushbutton in position MAN ...

Page 13: ...ASI Athletics Switcher Indoor Version 1 0 3373 502 02 Page 7 3 2 4 Cameras PRY 60M SDY 60M PRY 200M Track SDY 200M Track Timer ...

Page 14: ...ER 1 and POWER 2 If only power supplies are connected to the ASO add an Uninterruptable Power Supply UPS 3 3 2 Cameras 4 cameras can be connected to the ASO unit Primary 60M Secondary 60M cameras are positioned in the timing room Primary 200M Secondary 200M cameras could be installed in the track or in the timing room Select CELL if recording is started by FINISH photocell or MAN if started by a p...

Page 15: ...e 1920 010 3 3 4 Galactica Connect the Galactica computer INT131 with the cable 1871 xxx xxx cable length in meters 010 025 Only the running time is transferred same information as track scoreboards 3 3 5 Telephone Connect the telephone unit to the track with the cable 1878 xxx xxx cable length in meters 010 050 100 ...

Page 16: ... event select the switch in position Secondary 60 200M SDY Data will be immediately switched When camera Primary 60M or Secondary 60M is READY the corresponding led will light up When camera Primary 200M or Secondary 200M is READY the corresponding led will light up 4 3 Intermediate and Finish time 4 3 1 Intermediate time 1500M When the first racer arrives near the intermediate photocell press and...

Page 17: ...1 Power on your computer and boot to Windows 2 Put the driver CD in the CD ROM then run the PL 2303 driver See Fig 1 and 2 Fig 1 Fig 2 3 Connect Athletics Switcher PRY or SDY with your computer by USB cable 4 Windows will auto detect four new USB devices and start InstallShield Wizard See Fig 3 Fig 3 ...

Page 18: ...ver will auto assign a COM number from your system 1 2 Remove drivers Use the DRemover98_2k to remove INT131 driver Double click DRemover98_2k If INT131 driver software has already been installed the modify repair or remove the program window will appear then select Remove to clean INT131 driver completely It is necessary to update the driver when INT131 adds new features or functions Use the DRem...

Page 19: ...ASI Athletics Switcher Indoor Version 1 0 3373 502 02 Page 13 6 CONNECTORS DESCRIPTION ...

Page 20: ...utzklasse IP42 indoor use Working temperature Température de fonctionnement Betriebstemperatur 0 C to 50 C Temperature range storage Température de stockage Lagertemperatur 30 to 85 C 7 2 Electrical characteristics Power supply Alimentation Speisung External power supply Athletics Switcher 110 240 VAC 15VDC 10 30VDC Power consumption Consommation électrique Stromverbrauch Max 90 VA CE Standards ...

Page 21: ...I Athletics Switcher Indoor Version 1 0 3373 502 02 Page 15 8 APPENDICE 8 1 Index figures No table of figures entries found 8 2 Version history Version Modifications since last version 1 0 Initial version ...

Page 22: ...Page 16 3373 502 02 Version 1 0 NOTES ...

Page 23: ...Swiss Timing LTD Phone 41 32 488 36 11 P O Box 138 Rue de l Envers 1 info swisstiming com CH 2606 Corgémont Switzerland www swisstiming com ...

Reviews: