background image

 

SPECIFICATIONS 

 

Model # 

Objective 

M27LED-123 

M27LED-124 

Total Magnification 

1X 

10X 

10X 

  

2X 

20X 

20X 

  

3X 

30X 

NA 

  

4X 

NA 

40X 

  

 

 

 

Field of View 

1X 

20 mm 

20 mm 

  

2X 

10 mm 

10 mm 

  

3X 

6.7 mm 

NA 

  

4X 

NA 

5 mm 

  

 

 

 

Working Distance 

1X 

57 mm 

48 mm 

  

2X 

57 mm 

48 mm 

  

3X 

57 mm 

NA 

  

4X 

NA 

48 mm 

  

 

 

 

Depth of View 

 

0.17 – 1.05mm 

0.13 – 1.05mm 

 
Dimensions: 10”(L) X 5”(W) X 12.5”(H) 
 
Weight: 6.6 lbs 
 
Illumination: Top (Incident) LED 3.4V/0.3W 
                    Bottom (Trans-base) LED 3.4V/0.06W 
 

PARTS AND ACCESSORIES 

 

MA14773  LED Bulb for Top Light, 3.4V/0.3W 
MA14774  LED Bulb for Bottom Light, 3.4V/0.06W 
MA2609 

W15X Eyepieces, (pair) 

MA2610 

W10X Eyepieces, (pair) 

MA2615 

Stage Clips, (pair) 

MA2616 

Eyeshields, (pair) 

MA2620 

Black & White Stage Plate 

MA2621 

Frosted Stage Plate 

 

Summary of Contents for M27LED Series

Page 1: ...1 Swift M27LED Series Stereo Microscope Use and Care Manual SWIFT OPTICAL Enduring Quality and Technical Excellence...

Page 2: ...able field of view The M27LED incorporates features to enhance and provide maximum versatility of the instrument for classroom use It is built to rigid optical and mechanical standards The scope is th...

Page 3: ...the clutch system will slip to prevent damage to mechanical parts ILLUMINATION The top incident and bottom trans base illuminators are controlled by two on off switches located on the base of the mic...

Page 4: ...l system is now adjusted to your particular vision 5 Turn the turret to a higher power for increased magnification SERVICE Always unplug the microscope from the power outlet while performing service a...

Page 5: ...nsert the metal pins of the new bulb into the bulb socket 4 Reverse the previous steps to install the new LED bulb Note If the new bulb does not work after installation the polarity of the bulb may ha...

Page 6: ...urfaces should be cleaned frequently with mild detergent and a soft cloth TROUBLE SHOOTING A PROBLEM The image does not stay in focus CORRECTION Use Swift C Wrench MT202 to tighten the tension collar...

Page 7: ...NA 4X NA 48 mm Depth of View 0 17 1 05mm 0 13 1 05mm Dimensions 10 L X 5 W X 12 5 H Weight 6 6 lbs Illumination Top Incident LED 3 4V 0 3W Bottom Trans base LED 3 4V 0 06W PARTS AND ACCESSORIES MA147...

Page 8: ...FT OPTICAL INSTRUMENTS INC LIMITED LIFETIME WARRANTY Please see our website www swiftoptical com for complete warranty details and exclusions Swift Optical Instruments Inc 877 967 9438 www swiftoptica...

Reviews: