Swienty DANA api MATIC Instruction Manual Download Page 36

34

35

ENGLISH

DANA api MATIC 2000+ AND 3000

NO. DOC. NO.

REV. NO. TITLE

MATERIAL

Qty. ITEM NO.

1

dt-004-011-2

00

Pump housing

Rialan petp white 90x120x150

1 210038

2

dt-074-012-2

01

Pump cover

TECAPET white FG

1 210036

3

dt-074-016

02

Drive shaft f/Crane seal

A304-polished-h8 ø16x116

1 6074016

4

6002-B180_10_GL_1 Glas bearing

Con no. 505170

1 505170

5

dt-004-010A

00

Fitting

Stainless steel, Skal ø60x72

2 6004010A9F

6

dt-004-009

00

Accelerator shaft

Stainless steel, Blank ø16 h9x65

1 60040099F

7

dt-074-017

02

Clutch ø15

Con no. 504500

1 6074017

8

O-ring ø37x2

Con no. 508037

2 508037

9

O-ring BS 1.5

Con no. 500212

2 500212

10

O-ring ø96x3

Con no. 508096

1 508096

11

Fitting spring acid-proof 5x5x40

Con no. 502705

1 701019D

12

Fitting spring acid-proof 5x5x16

Nav no. 701013

1 701013

13

dt-004-008

00

Module 4 ø59,2x47 12T DC 51,2 Træk

Pom white

1 60040081F

14

dt-004-008

00

Module 4 ø59,2x47 12T DC 51,2 Medløb

Pom white

1 60040081F

15

dt-074-024

01

Bearing housing f/Crane seal

Stainless steel, 304 Skal ø65x46

1 60740249M0

16

O-ring ø30x1

Con no. 508030

1 508030

17

dt-074-028

03

Cover plate

Stainless steel, 304 1mm B

1 6074028F

18

Lock ring ø 15

Nav no. 701059C

1 701059C

19

M5x35 submerged Allen A2

Stainless steel, 304

4 700329

20

M6x10 Pinol A2

Stainless steel, 304

1 700433

21

00

M5x10 Buttonhead A2

Stainless steel, 304

2 700223

22

Shaft seal ø16

Con no. 508301

1 508301

Summary of Contents for DANA api MATIC

Page 1: ...Instruction manual DANA api MATIC...

Page 2: ......

Page 3: ...ENGLISH...

Page 4: ......

Page 5: ...eaning 17 Cleaning with long storage 20 Configuration options 22 Mounting the anti drip 23 Rubber diaphragm for filling nozzle 24 Rubber diaphragm with nozzle 24 Counterflow valve 24 Connecting equipm...

Page 6: ......

Page 7: ...ly hang up THE MACHINE MUST ALWAYS BE USED UNDER SUPERVISION The product falls under direktive 2002 96 EF on waste electrical and electronic equipment WEEE The product may not be disposed of together...

Page 8: ...ogram for different substances As a pump the machine works both ways and can be set to different speeds All parts that come into contact with the substance are made from food grade plastic or stainles...

Page 9: ...ram for different substances As a pump the machine works both ways and can be set to different speeds All parts that come into contact with the substance are made from food grade plastic or stainless...

Page 10: ...ogram for different substances As a pump the machine works both ways and can be set to different speeds All parts that come into contact with the substance are made from food grade plastic or stainles...

Page 11: ...nguage and Stop Back to leave the menu Next fill the pump head with the desired substance before you start using the machine and connect it to the supplied hose and fitting For medium or high viscosit...

Page 12: ...ss ENTER Choose the shown value and save it STOP BACK Stop the motor and interrupt the filling or pumping process Also function as a back button DISPLAY When the filling machine is connected to the po...

Page 13: ...o much air With the next filling the air will then loudly be pressed out again CALIBRATION To make sure that the amount shown on the display matched the filled amount the machine needs to be calibrate...

Page 14: ...ssibly hang it up NOTE never connect to power before the hose fitting and anti drip cut off valve with nut are mounted Optional connect a foot pedal Place a jar bowl under the pump housing Dilute the...

Page 15: ...he fittings can be tightened without tools Grasp the nut red arrow with your left hand and the fitting hose with your right hand Pull clockwise on the fitting and nut This is how to tighten the fittin...

Page 16: ...hen press STOP Open the valve of the container PREPARATION FOR FILLING After the machine stops dripping mount the cut off mechanism Can potentially be mounted first but not when filling very tough sub...

Page 17: ...a scale and press Z T tara to reset the scale Put the glass under the pump housing If necessary press and to change the filling amount Press ENTER to save and exit Before calibrating the machine you...

Page 18: ...Save by pressing CALIBRATE Potentially repeat the calibration if the difference between weight and filling amount is big The machine is now calibrated and ready for filling The machine must be set to...

Page 19: ...e notches at the end of the pump housing and gently pull the pump housing off the machine CLEANING Start the machine to empty the container and hose Loosen the connection fitting so air can come into...

Page 20: ...oupling This loosens the honey so it is easier to open the pump housing Open the pump housing Take out the loose gear as well as the axis that are still in the pump housing It can be necessary to rins...

Page 21: ...be lubricated with grease or the filling substance for extra sealing Put the pump housing together again Remember to check that the clutch teeth fit otherwise the pump housing cannot be put back on c...

Page 22: ...s and take off the plate Now you can pull out the axis bearings and gasket out by carefully pulling on the axis ATTENTION you must pull from the side you just took the plate off of Follow the cleaning...

Page 23: ...beginn the put everything together again Make sure that the bearing re arrow sits in the right position so that it aligns with the bearing housing Now the plate can be screwed on the claw coupling can...

Page 24: ...see page 23 ALSO POSSIBLE Less precise Counterflow valve can be useful here item no 110059 For mounting the anti dryp see page 23 If you are using a fixed pipe installation you need to install a piece...

Page 25: ...Holder f 20 Crossvalve with anti Machine name Holder f 20 Crossvalve Asmb NO st 075 608 st 075 603 Palle H Olsen Material H rtoftvej 16 Rageb l 6400 S nderborg Tlf 74486969 Fax 74488001 www swienty c...

Page 26: ...counterflow valve is placed on the pump housing s inlet fitting a Seal b Flow plate c Counter plate Existing law protects the above mentioned companys right of possesion to this drawing The design or...

Page 27: ...with the 3 pin connector on the turntable 1 Supply 24VDC max 4A 2 Signal to stop filling or pumping 3 Supply 0VDC GND 4 Signal to start filling or pumping 5 Signal that filling is done All signals are...

Page 28: ...amount are reached This parameter can also be set directly by using the SPEED button Start 2 Determines when the motor s speed should be changed to parameter SPEED 2 START 2 can be set from 1 to 100 o...

Page 29: ...with a turntable If you use the machine with a foot pedal TIME READY can be set as a break time between to fillings so you have time to remove the filled jar and place an empty jar under the nozzle TI...

Page 30: ...et the language to English German French Spanish or Danish by pressing All messages are shown in the chosen language Press ENTER to choose a language and Stop Back to leave the menu RESET In this menu...

Page 31: ...DIAGRAM MENU PARAMETER LOG P1 P20 KG PUMPED HOURS FILLING DANSK ENGLISH DEUTSCH FRANCAIS ESPANOL ITALIANO P1 P20 RESET CALIBRATION UNIT TIME READY ANTIDRIP TIMEADRIP SPEED 3 START 3 SPEED 2 START 2 S...

Page 32: ...000 P7 700 0 0 0 25 6 0 1 g 100 1000 P8 800 0 0 0 25 6 0 1 g 100 1000 P9 900 0 0 0 25 6 0 1 g 100 1000 P10 1000 0 0 0 25 6 0 1 g 100 1000 P11 1100 0 0 0 25 6 0 1 g 100 1000 P12 1200 0 0 0 25 6 0 1 g 1...

Page 33: ...ing housing and push pull the gasket and shaft seal off the drive shaft Then screw off the plastic part Then unscrew the cover plate The sealing gets positioned by pressing the plastic part in with yo...

Page 34: ......

Page 35: ...h9x65 1 60040099F 7 Fril b 00 Gear 51 5x52 Modul 5 8 DC 41 5 Con no 60543015F 1 60543015F 8 Tr khjul 00 Gear 51 5x52 Modul 5 8 DC 41 5 Con no 60543015F 1 60543015F 9 Mupu seal 30312 0160 90 s Con no...

Page 36: ...ring BS 1 5 Con no 500212 2 500212 10 O ring 96x3 Con no 508096 1 508096 11 Fitting spring acid proof 5x5x40 Con no 502705 1 701019D 12 Fitting spring acid proof 5x5x16 Nav no 701013 1 701013 13 dt 0...

Page 37: ...See AIR IN THE HONEY MACHINE DOESN T PUMP EVEN THOUGH IT STARTS 1 Have you filled the pump housing with your filling substance 2 Check if the pump direction is set correctly with the arrow s direction...

Page 38: ...s the same O RING IN THE PUMP HOUSING Thehoseispushedoverthefittinguptothebending Remembertoputthehoseclamponbefore Itistightened directlybehindthebulge TIP Putthehoseinwarmwaterfor halfaminute Checki...

Page 39: ...honey 0 051 oz honey IF YOU FIND MISTAKES OR HAVE SUGGESTIONS FOR IMPROVEMENT WE D BE HAPPY TO HEAR FROM YOU www swienty com shop swienty com Tlf 45 74 48 69 69 1 g honey 0 7 ml honey 1 g honey 0 035...

Page 40: ...500212 Handmountable nut for pump housing 502740 Cut off valve 20 110065D Dosing syringe 0 60 ml 115815 Nut BS 1 500110F DaM 1000 Nut for BS 1 fitting 500110F Foot pedal 110075 Cut off cross 20 compl...

Page 41: ...2 110210 Hex nipple 1 110221 Hex nipple 2 110211 Butterfly valve 1 110241 Butterfly valve 2 110240 Holder and switch 110045 Hose 1 FDA 90 110160 Hose 2 FDA 90 110170 Nozzle 9mm 110062 Nozzle 15mm 110...

Page 42: ......

Page 43: ......

Page 44: ...Swienty A S H rtoftvej 16 6400 S nderborg Danmark Tlf 45 74 48 69 69 shop swienty com WWW SWIENTY COM...

Reviews: