10
11
ENGLISH
FILLING
When the machine is turned on, the display shows the settings that have been used for the last
filling. Press the [START] button to begin filling. Furthermore you can start the machine with an
external start impuls, e.g. the included foot pedal. In the beginning the filling amount is 0 and it
then counts up to the set amount.
After that the motor stops immediately, takes a short break TIMEADRIP (se parameters) and
shortly rotates backwards.
This prevents the machine from dripping after the filling (see anti drip function [ANTIDRIP] ).
If you want to increase/decrease the shown amount, press the [+]/[-] buttons. The filling amount
blinks on the display.
When you have reached the desired amount, press the [ENTER] button. Now this amount is
connected to the program until you set it again.
ANTIDRIP
A problem with tough liquids like e.g. honey us that they can continue dripping after filling. To
prevent this from happening, we have developed a special rubber nozzle that minimizes this.
At the same time the motor rotates backwards for a short time to suck a small amount back in.
This amount depends on the consistency of the substance.
Press [ANTIDRIP]. The number blinking on the display stands for the return pulses. With the
[+]/[-] buttons the number can be changed (the higher the number, the more backflow). Save
with [ENTER]. If the number is too low, then the machine drips, if it is too high, then the machine
sucks in too much air. With the next filling the air will then loudly be pressed out again.
CALIBRATION
To make sure that the amount shown on the display matched the filled amount, the machine
needs to be calibrated.
Do a testrun anf measure it on a calibrated scale. If the display shows e.g. 500g but the scale
measures 520g, the value from the scale needs to be transfered to the machine.
With the [+] button you set the value to 520. The number blinks. Instead of saving with [ENTER],
you need to press [CALIBRATE]. The number on the display jumps back to 500g. Now the machine
is calibrated (in some cases this process needs to be repeated a few times).
MOTOR’S SPEED REGULATION
In some cases it can be necessary to regulate the pump capacity and thus the motor’s speed.
Press the [SPEED] button. The speed setting blinks. Using the [+]/[-] buttons you said the desired
speed in percentage. Save by pressing [ENTER]. Can be set in 5% intervals.
Th speed regulation can also be changed while the machine is filling or pumping. In connection
with a turn table it can be neccessary to decrease the speed to be able to follow along.
PUMPING
When the machine should be used as a pump, press [PUMP/FILL]. To change the pump direction,
press [DIRECTION]. The arrow on the display now points in the opposite direction.
Press [START] to start the pump. The pump amount starts at 0 and then counts up. To stop the
pump press the [STOP/BACK] button. The pumped amount blinks on the display. If you want to
continue pumping, press [START], then the machine begins to pump again and the pump amount
counts further up.
To reset the pump amount, stop the machine and press [STOP/BACK] again.