background image

 

Manufacturer  bears  no  responsibility  for 
damages  caused  by  non-observance  of  this 
manual.  

9.4

 

Control panel installation 

Possible  methods  of  installation  of  the  control 
panel on or in a wall. Drill a hole in the mounting 
plate acc. the below drawing or do it mounting 
the  panel  onto  mounting  screws  with  spacing 
indicated.  

 

 

 

 

 

Control  panel  mounting  requirements.  1 

 

control panel, 2 

 vent holes to provide air circulation.

 

 

 

 

Disassembly of control panel 

 
During panel de-installation (see fig. below), to 
remove the panel (1) from the casing, insert the 
flat  elements  (2)  into  gaps  indicated  in  the 
figure. It will cause the casing clamps to  open 
and allow you to remove the panel (1). 

 

A  proper  air  circulation  should  be  provided 
through  ventilation  openings  and  proper 
panel  housing,  not  to  exceed  a  maximum 
temperature of 40°C ambient panel. 

 

The  holes  may  not  cause  downgrading  of 
required  IP  rating.  They  are  not  required  if 
permitted  ambient  temperature  around  the 
control panel is not exceeded

.

 

Summary of Contents for TACtouch

Page 1: ...OPERATION ASSEMBLY MANUAL TACtouch CONTROL PANEL TO THE TAC5 TAC6 CONTROLLER 050371 20220503 ...

Page 2: ...ION 4 7 OPERATION OF THE PANEL 4 8 SOFTWARE UPDATE 5 9 ASSEMBLY 5 9 1 TECHNICAL DATA 5 9 2 EXPLOITATION CONDITIONS 5 9 3 ASSEMBLY REQUIREMENTS 5 9 4 CONTROL PANEL INSTALLATION 6 9 5 CONNECTING OF THE CONTROL PANEL 7 9 6 CLEANING AND MAINTENANCE PROCEDURES 8 10 CONNECTING TACTOUCH CONTROL PANEL TO THE TAC5 TAC6 CONTROLLER 9 11 LICENSES FOR OPEN SOURCE SOFTWARE 13 ...

Page 3: ...f materials of highest quality The product meets the requirements of the Directive 2012 19 EU of 4 July 2012 on waste electrical and electronic equipment WEEE according to which it is marked by the symbol of crossed out wheeled bin like below meaning that product is subjected to separate collection Responsibilities after finishing a period of using product dispose of the packaging and product at t...

Page 4: ...rs exit a chosen menu position or cancel a parameter setting quick return back to the main screen menu information concerning the selected menu position enter to the main menu Main screen if the heat exchanger is working main screen shows schematics with most important values like temperatures speed of fans date actual time etc To start the controller press anywhere on the screen with the words Co...

Page 5: ...hout condensation Display Graphic color 480x272pix with touch panel Terminal Ver 1 RJ11 Ver 2 Screw terminals Cross section 0 2 1 5 mm2 Dimensions 96 8x148 8x14 5 mm Weight 0 2 kg 9 2 Exploitation conditions Control panel do not expose the device to direct influence of atmospheric conditions rain sunlight nor vibrations stronger than typical occurring during wheel transportation do not use the dev...

Page 6: ...s to provide air circulation Disassembly of control panel During panel de installation see fig below to remove the panel 1 from the casing insert the flat elements 2 into gaps indicated in the figure It will cause the casing clamps to open and allow you to remove the panel 1 A proper air circulation should be provided through ventilation openings and proper panel housing not to exceed a maximum te...

Page 7: ...the controller The filter should be inserted on the cable necessarily in the form of a cable loop between the control panel and the controller module at distance about 120 mm from the control panel connector Installation EMC filter 1 control panel 2 TAC5 TAC6 controller module 3 EMC filter type ZCAT1518 073 The control panel should be installed with the mains supply disconnected from the controlle...

Page 8: ...ufacturer 9 6 Cleaning and maintenance procedures The outer surface and maintenance of the control panel screen The device should be cleaned with a soft dry cloth It is not allowed to clean the device with a flammable agent or substance i e benzene or any kind of solvents or a wet cloth Such treatment can lead to malfunction of the device It is not allowed to scratch the screen with nails or other...

Page 9: ...9 10 Connecting TACtouch control panel to the TAC5 TAC6 controller TAC5 TAC6 modbus Master writing Maximum cable length 100m ...

Page 10: ...10 TAC5 Slave wiring star with other devices in daisy chain Maximum cable length 100m ...

Page 11: ...11 TAC5 Slave wiring Maximum cable length 100m Shield ...

Page 12: ...12 Red Grey Blue Black TAC6 wiring ...

Page 13: ...f the FatFs license document that included in the source files FatFs Generic FAT file system module Rx xx Copyright C 20xx ChaN all right reserved FatFs module is an open source software Redistribution and use of FatFs in source and binary forms with or without modification are permitted provided that the following condition is met 1 Redistributions of source code must retain the above copyright n...

Page 14: ...ucts derived from this software without specific prior written permission THIS SOFTWARE IS PROVIDED BY THE AUTHOR AND CONTRIBUTOR S AS IS AND ANY EXPRESS OR IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED IN NO EVENT SHALL THE AUTHOR OR CONTRIBUTOR S BE LIABLE FOR ANY DIRECT INDIRECT INCIDENTAL SPECIAL EX...

Page 15: ...15 ...

Reviews: