ELQZ-4-613-0

*

*

Wiring example

BCRWD: sizes 006-020 (motor: 6.5 kW)
(WEG motor)

Note that all the cables must be shielded.

Two-speed control of one fan

Shielded terminal box

Shielded terminal box

Shielded terminal box

Conductors in motor cable

Conductors in motor cable

Conductors in motor cable

In-operation output
In-operation output
Alarm output
Alarm output
Start
GND (earth)
0-0V + input
0-0V + input
0V DC out (max 0mA)
GND (earth)
Alarm reset

In-operation output
In-operation output
Alarm output
Alarm output
Start
GND (earth)
0-0V + input
0-0V + input
0V DC out (max 0mA)
GND (earth)
Alarm reset

In-operation output
In-operation output
Alarm output
Alarm output
Start
GND (earth)
0-0V + input
0-0V + input
0V DC out (max 0mA)
GND (earth)
Alarm reset

Contact for switchover 
between low speed 
and high speed.

If only one fan can be con-

trolled, wire according to the 

uppermost alternative.

Single-speed control of two fans

* Must be closed when the unit is operating.

Summary of Contents for ELQZ-4-613-0

Page 1: ... with fasteners for mounting it on a 35 mm DIN rail and is designed for installation inside a cubicle or a similar enclosure Technical data Installation of the ELQZ 4 613 0 Fan speed changeover switch Power supply 24 V DC 15 V DC or 10V DC Power consumption 2 x 12 mA Signal output 0 10 V DC Corresponds to 0 100 on the pot Permissible ambient temperature 10 40 C Mounting bracket 35 mm DIN rail Encl...

Page 2: ...le speed control of two fans Two speed control of one fan Shielded terminal box Shielded terminal box GND Common Alarm output 0 10V input 10V DC out BCRWD 004 Start GND Common Alarm output 0 10V input 24V DC out Start Conductors in motor cable Conductors in motor cable Conductors in motor cable Shielded terminal box GND Common Alarm output 0 10V input 10V DC out BCRWD 004 Start Contact for changeo...

Page 3: ...tor cable Conductors in motor cable In operation output In operation output Alarm output Alarm output Start GND earth 0 10V input 0 10V input 10V DC out max 10mA GND earth Alarm reset In operation output In operation output Alarm output Alarm output Start GND earth 0 10V input 0 10V input 10V DC out max 10mA GND earth Alarm reset In operation output In operation output Alarm output Alarm output St...

Page 4: ...erminal box Shielded terminal box Shielded terminal box Conductors in motor cable Conductors in motor cable Conductors in motor cable GND Common Alarm output 15V DC out Start 0 10V input 0 10V input 10V DC out max 10mA Reset GND Common Alarm output 15V DC out Start 0 10V input 0 10V input 10V DC out max 10mA Reset GND Common Alarm output 15V DC out Start 0 10V input 0 10V input 10V DC out max 10mA...

Reviews: