Swegon ELQZ-4-613-0 Installation Download Page 2

GB.ELQZ613.050901

Specifications are subject to alteration without notice.

     www.swegon.se

1

2
3

1

2
3

1
2
3
4
5
6
7

8

1

2

3

4

5

6

7

ELQZ-4-613-0

BCRWD

BCRW

*

8

1

2

3

4

5

6

7

1

1

1

1

2

2

3

3

2

2

BCRWD

BCRW

1
2
3
4
5
6
7

1
2
3
4
5
6
7

ELQZ-4-613-0

*

*

Wiring exampel

BCRW size 004 
(GRUNDFOS motor)

Note that all the cable must be shielded.

Single-speed control of two fans

Two-speed control of one fan

Shielded terminal box

Shielded terminal box

GND
Common
Alarm output

0-10V input
10V DC out (BCRWD 004)
Start

GND
Common
Alarm output

0-10V input
24V DC out
Start

Conductors in motor cable

Conductors in motor cable

Conductors in motor cable

Shielded terminal box

GND
Common
Alarm output

0-10V input
10V DC out (BCRWD 004)
Start

Contact for 

changeover 

between low 

and high 

speed

If only 1 fan is to be controlled, connect as top alternative.

* Must be closed when the unit is operating.

Summary of Contents for ELQZ-4-613-0

Page 1: ... with fasteners for mounting it on a 35 mm DIN rail and is designed for installation inside a cubicle or a similar enclosure Technical data Installation of the ELQZ 4 613 0 Fan speed changeover switch Power supply 24 V DC 15 V DC or 10V DC Power consumption 2 x 12 mA Signal output 0 10 V DC Corresponds to 0 100 on the pot Permissible ambient temperature 10 40 C Mounting bracket 35 mm DIN rail Encl...

Page 2: ...le speed control of two fans Two speed control of one fan Shielded terminal box Shielded terminal box GND Common Alarm output 0 10V input 10V DC out BCRWD 004 Start GND Common Alarm output 0 10V input 24V DC out Start Conductors in motor cable Conductors in motor cable Conductors in motor cable Shielded terminal box GND Common Alarm output 0 10V input 10V DC out BCRWD 004 Start Contact for changeo...

Page 3: ...tor cable Conductors in motor cable In operation output In operation output Alarm output Alarm output Start GND earth 0 10V input 0 10V input 10V DC out max 10mA GND earth Alarm reset In operation output In operation output Alarm output Alarm output Start GND earth 0 10V input 0 10V input 10V DC out max 10mA GND earth Alarm reset In operation output In operation output Alarm output Alarm output St...

Page 4: ...erminal box Shielded terminal box Shielded terminal box Conductors in motor cable Conductors in motor cable Conductors in motor cable GND Common Alarm output 15V DC out Start 0 10V input 0 10V input 10V DC out max 10mA Reset GND Common Alarm output 15V DC out Start 0 10V input 0 10V input 10V DC out max 10mA Reset GND Common Alarm output 15V DC out Start 0 10V input 0 10V input 10V DC out max 10mA...

Reviews: