![Swegon CASA W3 XS Smart Installation, Commissioning And Maintenance Instructions Download Page 10](http://html1.mh-extra.com/html/swegon/casa-w3-xs-smart/casa-w3-xs-smart_installation-commissioning-and-maintenance-instructions_1413532010.webp)
10
W3/W4.170420
All rights to changes reserved.
www.swegon.com
2.8 Smart automation packages
• Auto humidity control
(SRH)
• Auto Home/Away/Boost fu Auto humidity
control
(SRHCO2)
• Auto Air Quality c Auto humidity control
(SRHVOC)
.
The ventilation unit has a connection cable for the
sensor package. The sensor package is secured with a
clip on the bottom of the case. The installation position
for the Sensor package is located behind the summer
bypass damper in the extract air chamber.
The position of the sensor package in the ventilation
unit is shown in the image below. The extract air filter
and the heat exchanger must be dismantled from the
ventilation unit, and the summer bypass damper must
be set to the “winter” position, while the installation is
performed.
All sensor combinations are encapsulated in the same
way. If there is a sensor package version installed in
the ventilation unit, you can replace it with an optional
sensor package. See the section
Functions and use
for
information about the automatic functions.
2.9 Accessories
Installation instructions for accessories are included in
the delivery of the each product.