background image

HOME VENTILATION

6

Swegon reserves the right to alter specifications.

www.swegon.com/

Optional equipment

Premium cooker hood

•  A cooker hood specifically designed for connection to the 

type R85 ventilation unit. The cooker hood can be connected 
via duct or directly to the ventilation unit.

•  Integrated control panel for the ventilation unit.
•  Neutral and stylish design.
•  Low sound level.
•  High capacity for arresting cooking odours thanks to the large 

hood.

•  A large grease filter made of metal.
•  Easy to clean. The grease filter can be washed in a dish wash-

ing machine.

•  ∅

 125 mm extract air connection. The connection spigot is of 

such a size that the hood can be mounted directly below the 
ventilation unit.

•  11 W fluorescent lamp.
•  Electrical connection from the R85 unit, 230 V, 10 A, for 

installation under the ventilation unit.

Alternative colours

•  White or stainless steel.

Optional equipment for the ventilation unit

Premium control panel

The control panel can be installed at an optional location, re-
cessed in a junction box or surface mounted on a wall. It can be 
located near the ventilation unit or somewhere else, and then 
must be connected to the unit via a 20 metre long modular 
cable. An extra control panel can also be connected, if it is de-
sirable to control the ventilation unit from several places. 

Front plate of the door

The ventilation unit is supplied as standard with a white door. 
As an optional extra, the door’s front plate can be ordered in a 
version made of stainless steel.

Reheating cassette

The 500 W electric air heater for reheating the supply air down-
stream of the heat exchanger is a factory-fitted, optional item of 
equipment. The air heater is switched on when the temperature 
of the supply air is below a preset value. The heater is wired by 
means of quick-fit connectors.

Mounting frame for ceiling/wall installation

Mounting frame with quick-fit connectors for mounting the 
ventilation unit on the ceiling or wall

Mounting frame with moisture barrier

The mounting frame has a moisture barrier which prevents 
moisture from entering the insulation in the attic joist floor and 
stops the air from the loft from coming down into the rooms.

Replacement filters

There are 2 class F7 fine filters in the set of filters.

Premium control panel

The front plate is available in the following colours: white and 
stainless steel.

Replacement filters

Reheating cassette

Roof mounting frame

Mounting frame with moisture barrier

Premium Classic cooker hood

Summary of Contents for CASA R85 Series

Page 1: ...sound level For installation in a kitchen machine room storage space laundry room etc Can also be located together with a cooker hood at the place intended for a spice rack above the cooker The extra...

Page 2: ...in the lower speed range The power supply and control cables have quick fit con nectors and the fans can be easily removed from the unit if required Filters The ventilation unit has class F7 fine fil...

Page 3: ...ilation rate may even be as much as 30 less than planned If the air change rate is less than anticipated the venti lation system s capacity for extracting moisture out of the home will not be sufficie...

Page 4: ...r programs You can set the desired times if you want the unit to activate a desired function The unit runs in the economical minimum speed mode at other times Away Functions Home Away Boost Cool You c...

Page 5: ...ing the room when you light the log fire Negative pressure compensation When the cooker hood is in use negative pressure arises in the home since the extract airflow becomes substantially higher than...

Page 6: ...ed to the unit via a 20 metre long modular cable An extra control panel can also be connected if it is de sirable to control the ventilation unit from several places Front plate of the door The ventil...

Page 7: ...hoods are sized specifically for connection to the ventilation unit with Premium control engineering If you do not want to connect the cooker hood to a ventilation unit you can select a controllable...

Page 8: ...good alternative for replacing an old cooker extraction fan with a new one is to install the ventilation unit as you would a wall cabinet on the wall above the cooker by means of the wall mounting bra...

Page 9: ...l s Thick line SFP 2 0 or lower Extract air flow Available pressure Pa Airflow l s Total output W Airflow l s Power consumption R85 R85 X L Connection 230 V 50 Hz 1 1 A 230 V 50 Hz 3 3 A Fans 238 W 23...

Page 10: ...17 45 80 59 62 52 45 35 27 20 49 90 60 65 55 48 38 30 23 13 52 100 62 68 57 50 40 32 25 15 55 Sound emitted to extract air duct Acoustic data Fan setting Sound power level broken down into octave ban...

Page 11: ...26 49 70 61 63 55 50 44 37 30 16 52 80 67 66 59 53 47 40 35 22 56 90 69 69 62 56 49 43 37 26 59 100 70 72 65 59 51 45 41 30 61 Sound emitted to kitchen bypass duct Sound emitted to the surroundings E...

Page 12: ...ium control panel e g for entering settings or service work Cable with modular connectors Premium control panel R85 Cable with modular connectors Control from a Premium control panel Mains power plug...

Page 13: ...Alarms Humidity sensor Carbon dioxide sensor temperature sensor Presence detector Misc 4 x 0 5 2 x 0 5 4 x 0 5 2 x 0 5 Modbus RTU See separate instructions E g 6 x 0 5 Example diagram 2 PREMIUM CONTR...

Page 14: ...sation 2 x 0 5 230 V 10 A 230 V 10 A Modbus gateway W80 EC W100 EC W130 EC W230 EC R85 EC R120 EC Home Away Boost 24 hour weekly timer Fireplace switch Alarm Humidity sensor Carbon dioxide sensor temp...

Page 15: ...xhaust air 125 Cooker hood s exhaust air 100 Wall mounting bracket 4 1 3 2 K 4 1 3 2 K K K Swegon CASA R85 L Top Bottom Swegon CASA R85 R Variants Right hand or left hand version In order to facilitat...

Page 16: ...iling wall installation R right hand version PR085RKA L left hand version PR085LKA Mounting frame with moisture barrier PR085YP Water trap UVL Front plate of the front panel Stainless steel PR085B6R F...

Reviews: