HOME VENTILATION
12
Swegon reserves the right to alter specifications.
www.swegon.com/
Power connection
The unit has a 230 V, 10 A mains plug connection.
Total power consumption
Excl. air heater for reheat: 250 W, 1.1 A
Incl. air heater for reheat: 750 W, 3.3 A
Control from a Premium cooker hood
The supply includes one 3 m long cable with modular connec-
tors, which are used for connecting the ventilation unit, cooker
hood, control panel and the Modbus Gateway adaptor. The
modular cable should be installed in a min.
∅
20 mm conduit.
For installation in a kitchen, you will find the control cable and
voltage measurement contacts of the cooker hood at the bot-
tom of the ventilation unit behind the cover plate.
Premium control via Modbus Gateway
Cooker hood
(no provision for power
cord extension)
Premium
control panel
Modbus gateway.
Modbus RTU
R85
Mains power plug
connection
230 V, 10 A
Premium control panel, e.g.
for entering settings or service work
Cable with modular connectors
Premium
control panel
R85
Cable with modular connectors
Control from a Premium control panel
Mains power plug
connection
230 V, 10 A
Extra control
panel
R85
The ventilation unit installed in a kitchen
Cooker hood beneath the ventilation unit.
Mains power plug
connection
230 V, 10 A
Extra control
panel
Premium
control panel
Cooker hood
(no provision for power
cord extension)
Premium
control panel.
If the control panel
is installed, connect
the cooker hood’s
modular cable to
the control panel.
Mains power
plug connection
230 V, 10 A
The ventilation unit installed in another space
Kitchen bypass on the top.
The modular cable located on
the bottom of the ventilation
unit behind the cover plate can
be used for adjustments and
servicing.
R85
Control from a Premium control panel
The control panel can be placed at an optional location. You
can supplement it with an extra control panel for instance, if
you want to remote control the ventilation unit from several
places or from a Modbus gateway.