background image

 

18 

 

To insert and/or enter a new label name, press  OK . Select character with 

 / 

. Press 

OK  to set. 

 

When settings are done, press  X .  

 

Press  OK  to save & exit. 

 

Press  X  to exit & discard. No changes will be made.  

 
 

SHUTDOWN OVER DMX: 

 

By using this function, the machine can be switched off & on using a 3

rd

 DMX channel for 

control.  The  function  is  suitable  for  remote-controlled  on  &  off  via  DMX.  The  control 
signal is detected on the 3

rd

 channel = start a 2. For example: Start address = 

100, shutdown is controlled with address 102.   

 

 

Enable  or  disable  shutdown  over  DMX.  Enabled  =  machine  uses  3  DMX  channels, 

Disabled = machine uses 2 DMX channels. Factory default is enabled (3 ch).  
 

 

NOTE:  If  you  don t  intend  to  use  shutdown  over  DMX,  disable  this  function,  for  two 
reasons;  1)  to  avoid  unwanted  switch-off  by  mistake  because  machine  detects  a  DMX 
signal intended for other equipment, and 2) to reduce the no. of DMX channels in use.    
 

 

Automatic shutdown (switch off) process starts at DMX level 220 (87 %)   239 (93 %) only. 
Below or above this level, the machine will operate as normal. If the DMX signal is lost 

during the 1-minute switch-off purging cycle, the machine will continue the switch-off 
cycle and go to standby mode when completed.  

 

 

In standby mode, the machine continues detecting DMX signal and will start heating up 
at DMX levels below 87 / above 93%. 
 

 

If the DMX signal is lost during standby mode, the machine will remain in standby. Same 
if the machine is on, it will remain on until a control DMX signal is detected.  
 

 

In  standby  mode,  the  machine  will  continue  detecting  DMX  signal,  meaning  if  DMX  is 
detected, the shutdown / switch-on function is active.     

 
FLUID SENSOR: 

 

The  machine  uses  a  flow  sensor  to  detect  an  empty  fluid  container.  If  no  flow  is 
detected, a  fluid empty  message appears and fog production is stopped to protect the 
fluid pump from running dry for a longer period. 
The function of the flow sensor may be disturbed if there are air bubbles in the fluid 
line. Air bubbles appear at container change when the connector is removed. Also, the 
fluid  bag  contains a  small  volume  of  air,  which  normally will be  sucked  into  the  fluid 
line when the bag is empty or almost empty.  
For normal use, it is recommended to keep fluid sensor enabled. In some situations, it 
might  be  suitable  to  disable  the  sensor,  for  example,  if  the  machine  is  used  at  a  low 
output  setting,  it  may  take  a  very  long  time  for  the  pump  to  prime  &  air  bubbles  are 
gone. Also, if external containers are used, and/or if longer suction hoses are used, air 
bubbles may interfere with the flow sensor.  
To avoid unwanted & unnecessary interrupt, disable the sensor and maintain control of 
the fluid container to avoid the machine from running dry for a long period.  
Enable the sensor again if the machine is used under normal conditions, to avoid the 
risk of fluid pump wear out.     

 

 

Choose  Enable  or  Disable , press  OK  to confirm. Press  X  to exit. 

 

MUTE POWER LED: 

 

If there are requirements of the  invisible  appearance of the machine, for example on a 

dark stage, all LEDs and the display can be muted. Choose  Mute Power LED  to keep the 
power LED Off. 

 

 

Select  Unmuted  for normal operation. 

 Continued 

Summary of Contents for K1 HAZER

Page 1: ...K1 HAZER 40510 230 K1 Hazer EU version Rev 1 2019 10 03...

Page 2: ...tage et de faire fonctionner cet quipement WICHTIG Lesen Sie alle Warnungen sorgf ltig bevor Sie das Ger t zusammenbauen installieren und benutzen IMPORTANTE Por favor lea todas las precaucionas y las...

Page 3: ...ONS 7 6 OPERATION 8 6 4 Operation Menu system user interface 14 6 5 Operation Fluids 20 7 Specifications 21 8 Service maintenance repair 21 8 2 Error service messages 22 9 WARRANTY RETURNS 26 CE CONFO...

Page 4: ...pport online In this manual you will find the following symbols CAUTION This symbol appears adjacent to caution messages Not heeding these messages could result in minor personal injury and or damage...

Page 5: ...r approx 5 hours at full 100 output and theoretically up to 300 hours at 1 Estimated for most normal venues a 3L container will last for 8 20 hours of normal use but depends on capacity requirements K...

Page 6: ...pery surface can cause serious personal injury ALWAYS check surfaces before during and after use of the machine Use Swefog K1 molecular fluid only Other fluids may damage the machine cause residues in...

Page 7: ...at exchanger and cause damage to the machine not covered by warranty NOTE If there is a fluid leakage or spillage wipe off fluid DO NOT use the machine until it is mended NOTE The haze may cause resid...

Page 8: ...et 2 Fan air outlet 3 Wave guide 4 Air inlet 5 Control panel display 6 Ergonomic AluGrip handle 7 Fluid container compartment 8 Latch 9 Illuminated fluid level indicator 10 USB connector type B 11 XLR...

Page 9: ...earth lead machine consumes 6 5 amps max The machine will automatically start up when connected to mains Heat up time until ready is approx 1 minute Open fluid compartment release latch 8 and open th...

Page 10: ...t drops onto the cellulose cloth below the connector Replace cloth when necessary Open prepare a 3L K1 molecular fluid container by following instructions printed on container NOTE K1 hazer uses fluid...

Page 11: ...11 The spout flange shall be positioned in the rail between the black stainless metal plates Push in spout to center position Check container slips behind the edge of the fluid container assembly...

Page 12: ...ard about 3 mm push black tube connector assembly towards container spout until it to correct fully connected position Release locking ring Test proper connection by pulling the tube connector NOTE In...

Page 13: ...iner change Do not unplug mains supply until the machine has completed the 1 minute switch off purging cycle and is in standby mode Unexpected power loss may cause permanent damage to the heat exchang...

Page 14: ...nd user settings and will look different depending on what function currently active For example in DMX mode below the address number is presented with large digits while output levels are presented a...

Page 15: ...ed off CHOOSE HOW TO CONTROL THE MACHINE Set control mode DMX Manual Timer mode DMX MODE uses standard DMX512 A USITT protocol DMX mode has 3 tabs Address fog fan Change start address in the Address t...

Page 16: ...YES No BOOT_SOFTWARE_VERSION_ID 0x00C1 YES No Software ver ID higher number newer ver BOOT_SOFTWARE_VERSION_LABEL 0x00C2 YES No Human readable software version Higher number newer ver DMX_PERSONALITY...

Page 17: ...ay time is 9 hours 59 min 59 sec 9 59 59 For safety reasons timer is always pre set as OFF Start timer operation in I O tab press OK to start stop timer All settings can be changed during timer operat...

Page 18: ...DMX signal is detected In standby mode the machine will continue detecting DMX signal meaning if DMX is detected the shutdown switch on function is active FLUID SENSOR The machine uses a flow sensor...

Page 19: ...r many hours of use If it is not necessary the display is always on keep screensaver function enabled Select Muted for normal operation The display is off after 30 sec Select Unmuted and display will...

Page 20: ...companies when a machine is returned by a customer use this function to delete all user settings and clean settings for the next customer Default factory settings in short Operation mode is DMX start...

Page 21: ...will be able to perform most service works K1 uses air filter mats covering all air in outlets on the machine housing s and several air filters to protect internal components from damage Filter mats...

Page 22: ...To protect the machine from damage and or unstable operation it will remain in interrupt mode until the power supply is stable Check voltage with a True RMS digital multimeter Disturbance Severe distu...

Page 23: ...anger to protect components the machine will go to interrupt mode Possible cause Heat exchanger may be clogged If this occurs fluid will be forced in the wrong direction through the air line tube To p...

Page 24: ...efore the parameter shall be considered as a convenient assist only to monitor service intervals of your machine rather than a strict schedule for replacement To reset the lifetime of air pump filter...

Page 25: ...p fluid pump Reset can be performed before or after the component s calculated EOL NOTE Reset service messages ONLY when the concerned component has been replaced False resets without replacing the wo...

Page 26: ...ler to check if the problem is able to solve without sending the machine back See FAQ service bulletins published on swefog com Also always check for firmware updates and make sure to update to the la...

Page 27: ...s norms generic immunity standard generischer Immunit tsstandard norme d immunit g n rique EN 60335 1 electrical safety elektrische Sicherheit S curit lectrique Therefore the product fulfills the de 2...

Page 28: ......

Reviews: