![Swefog K1 HAZER Owner'S Manual Download Page 16](http://html1.mh-extra.com/html/swefog/k1-hazer/k1-hazer_owners-manual_1413345016.webp)
16
RDM CONTROL (ANSI E1.20):
The machine can be controlled via a RDM ANSI E1.20 protocol. This is an intelligent bi-
directional communication using the standard DMX 512 link. The light console is able to
discover, read and configure the machine. The type of parameters and functions available
may be different depending on model configuration. Supported parameters:
RDM Parameter ID:
Value:
GET
SET
Default text / number:
allowed
allowed
DISC_UNIQUE_BRANCH
0x0001
DISC_MUTE
0x0002
DISC_UN_MUTE
0x0003
QUEUED_MESSAGE
0x0020
YES
No
STATUS_MESSAGES
0x0030
YES
No
E120_STS_LOW_FLUID, E120_STS_READY,
E120_STS_NOT_READY, E120_STS_OVERTEMP,
E120_STS_UNDERTEMP
STATUS_ID_DESCRIPTION
0x0031
YES
No
SUPPORTED_PARAMETERS
0x0050
YES
No
DEVICE_INFO
0x0060
YES
No
PRODUCT_DETAIL_ID LIST
0x0070
YES
No
PRODUCT_DETAIL_FOGGER_GLYCOL
DEVICE_MODEL_DESCRIPTION
0x0080
YES
No
K1EU
MANUFACTURER_LABEL
0x0081
YES
No
Swefog
DEVICE_LABEL
0x0082
YES
YES
K1
SOFTWARE_VERSION_LABEL
0x00C0
YES
No
BOOT_SOFTWARE_VERSION_ID
0x00C1
YES
No
Software ver ID, higher number = newer ver.
BOOT_SOFTWARE_VERSION_LABEL
0x00C2
YES
No
Human readable software version.
Higher number=newer ver.
DMX_PERSONALITY
0x00E0
YES
YES
select personality & see personality selected
DMX_PERSONALITY_DESCRIPTION
0x00E1
YES
No
Fog, Fan, Control *
* Control alternative enabled only if shutdown
over DMX is enabled, see system settings.
DMX_START_ADDRESS
0x00F0
YES
YES
SENSOR_DEFINITION
0x0200
YES
No
&
SENSOR_VALUE
0x0201
YES
No
Values for above temperatures
IDENTIFY_DEVICE
0x1000
YES
YES
MANUAL MODE:
•
Manual mode uses 3 tabs: Fog, fan, on/off.
•
Current fog output & fan speed is displayed in the main window with bars, independent
of what tab that is active. NOTE: Fan always runs at 10% at idle / fog off.
•
To set fog output: Activate Fog tab, set output 0-100% using
▲
/
▼
. Actual setting in %
is shown in display.
•
To set fan speed: Activate the Fan tab, set speed 11-100% using
▲
/
▼
. The actual
setting in % is shown on the display. NOTE: below 11%, fan speed = AUTO , and follows
fog output.
•
Fog on / off: Activate ON/OFF tab, press OK to start & stop fog production.
•
NOTE: Fog production can be stopped in any tab by pressing X .
Summary of Contents for K1 HAZER
Page 1: ...K1 HAZER 40510 230 K1 Hazer EU version Rev 1 2019 10 03...
Page 28: ......