6
Please power off the unit and check. Restart the
unit after trouble-shooting.
IV. Operation
1
:
:
:
:
Check before start
1-1. Make sure if power source and electrical
connections comply with local electrical
regulations, equipped with NFB (Non Fuse
Breaker)
and earth wiring.
1-2. Check set bolts and nuts if looseness.
1-3. Check if electrical cables are correct.
1-4. Check if voltage is correct.
2
:
:
:
:
Check under operation
2-1. Check if compressed air pressure rises normally.
2-2. Check if loading current of motor remains in
standard level.
2-3. Check if all safety device work properly by hand.
2-4. Never touch cover under operation. Stay away
from high heat components, motor, and fan to
avoid injury.
2-5. For long lasting life, the rate of loading cycle is
suggested to be not over 70%.
V. Maintenance
1
:
:
:
:
Daily maintenance
1-1. Release water from air tank after daily use.
(Please implement under 1kg/cm².G)
1-2. Check if compressed air pressure rises normally in running.
1-3. Clean compressor cover on both sides to
always keep inlet valve clean.
1-4. Check if abnormal sound or vibration happens.