III. Installation and precautions 
   

1. Installation essentials 

1-1. Please install the unit in position where it is easy 

      to do maintenance and good ventilation. 

1-2. Do not install in damp or dusty places. 
1-3. Install on flat and firm ground to prevent from 

      slipping. 

   

2. Electric wiring 

2-1. Ensure the voltage and frequency is correct. 
2-2. For safety reason, always follow electricity 

      instructions, and equipped with NFB (Non Fuse 

  Breaker).Besides, the power voltage should not be 
  lower than 90% of the required standard voltage. 

2-3. The joint of power supply should be fixed firmly 

  to avoid any disconnection and break down. 

3. Protection points 

3-1. The unit is equipped with pressure switch to avoid 

      pressure too high: when air tank pressure reaches 
      to the upper pre-set value, the pressure switch will 
      cut-off the motor power to stop operating the unit. 

(stand-by condition). 

3-2. When the unit is in stand-by condition and air 

      pressure drops to the pre-set lower value, the 
      pressure switch will resume to “ON”, and the 
      motor will re-start to operate. 

3-3. Safety valve is fitted to prevent over-pressure; 

over-temperature protection is equipped to protect 
the motor.   

3-4. While abnormal high temperature occurs, the 

      motor protection switch will be actuated to shut 
      off the motor and stop running the unit. 

Summary of Contents for DRS SERIES

Page 1: ...DRS SERIES OIL LESS AIR COMPRESSOR OPERATION MANUAL...

Page 2: ...h parts not manufactured by Tong Cheng serviced by unauthorized personnel or where recommended maintenance procedures have not been followed the warranty will be waived automatically This compressor i...

Page 3: ...escription function 4 III Installation and precautions 5 IV Operation 6 V Maintenance 6 VI Trouble shooting 8 APPENDIX I Air compressor configuration 10 APPENDIX II Electric circuit diagram 11 APPENDI...

Page 4: ...tor inside 1 5 Air discharge tube is made of stainless steel 2 Components of control system 2 1 Reliable components pressure switch check valve pressure gauge solenoid safety valve 3 Air tank 3 1 Inne...

Page 5: ...2 Tank pressure gauge Indicate air tank pressure 3 Safety valve Tank over pressure protection 9 Air tank Store compressed air 4 Quick Coupling Discharge outlet 10 Electric cord plug Ensure correct vol...

Page 6: ...supply should be fixed firmly to avoid any disconnection and break down 3 Protection points 3 1 The unit is equipped with pressure switch to avoid pressure too high when air tank pressure reaches to t...

Page 7: ...r pressure rises normally 2 2 Check if loading current of motor remains in standard level 2 3 Check if all safety device work properly by hand 2 4 Never touch cover under operation Stay away from high...

Page 8: ...month 300 hours 2 Periodically maintenance Item Weekly Monthly Yearly 2 Year Air tank drain valve Check and clean inlet air filter element Check and clean the ventilation area of the unit Check pressu...

Page 9: ...V Defective pressure gauge V Solenoid valve leaking V V Safety valve leaking V V Abnormal pressure Defective pressure gauge V Pressure switch worked improperly V V Defective solenoid valve V V Abnorm...

Page 10: ...g broken V V Fault motor V V Connecting rod loose V V Crankshaft loose V V Unable to start Motor fail to start Low voltage V V Capacitor broken V V Electric wiring is loose V V Motor current protector...

Page 11: ...iver Description NO NO 8 9 10 5 Drain valve assembly Check valve assembly 6 7 Pressure gauge Cable with plug Pressure switch 11 Hose 12 Solenoid valve 13 Anti vibration pads Description 1 13 4 14 8 9...

Page 12: ...11 APPENDIX II Electric circuit diagram Symbol Description P S SV Pressure switch Solenoid valve MC Compressor motor C Motor capacitor Over heat protector F PE Earth wire L1 L2 Electric cord...

Page 13: ...olenoid valve Motor Description Symbol SV PG 1 CV Air tank Check valve AT PS Ssfety valve Pressure switch DV BV PR Description PG 2 QC Pressure regulator Pressure gauge Outlet Quick coupling M SOL SF...

Page 14: ...TONG CHENG IRON WORKS CO LTD No 16 Ta Chin St Sec 2 Taichung Taiwan Tel 886 4 22612135 Fax 886 4 22628246 Web site www swanair com tw E mail swantc swanair com tw M01865H300E A...

Reviews: