background image

Framework Construction

1.

Measure the actual bathtub prior to building or
modifying the stud wall framework to determine the
exact size required.

2.

Add 3/8” to the width measurement and at least
3/16” or more to the depth measurement of the
bathtub to correctly size the framework opening.

3a. For new construction, build a wood or steel stud

framework for the bathtub enclosure.  Dry fit the
bathtub to ensure the recommended dimension
exists between the bathtub, the side wall framework,
and the back wall framework.

If installing a Swan Corporation Alcove Wall Kit in
conjunction with the bathtub, note that the alcove side
panels are designed to extend out past the edge of the
bathtub.  Read the Alcove Wall Kit installation manual and
build the framework to the specifications outlined in that
publication.

Note

: When constructing or modifying stud wall

framework, make sure to install (gang) multiple studs to
provide support for any required moisture resistant wall
board, solid surface panel attachment flanges, or filler
boards, etc.  The framework depth must be at least
3/16” more than the actual depth measurement of the
bathtub.  The illustration below shows a framework
depth of 31-1/2”, which is greater than the minimum.

3b. For existing construction, dry fit the bathtub to make

sure it fits correctly in the bathtub enclosure
framework.  If necessary, modify the framework to
achieve the proper bathtub fit.

Example 1

If the bathtub is to be installed in conjunction with Swan
Corporation solid surface wall panels or alternate wall
panels/ceramic tile, the following procedures must be
followed.

1.

After the bathtub installation is complete, install 
1/2” moisture-resistant wall board, as shown.

2.

The Swanstone or alternate bathtub wall material
will then be installed over the 1/2” moisture-resistant
wall board and bathtub flange, as shown.

To prevent possible water (wicking affect) damage to the
wall, the wall board must have a 1/2 inch gap above the
bathtub flange lip, as shown below.

BT-004

SWANSTONE

TUB WALL PANEL

OR ALTERNATE

TUB WALL PANEL

2 x 4 STUD

BATHTUB
FLANGE

MOISTURE
RESISTANT
DRYWALL (1/2”)

IMPORTANT NOTICE

BT-002

IMPORTANT NOTICE

800-325-7008

9

The Swan Corporation – Swanstone

Installation Procedure

Summary of Contents for BT-3060 L

Page 1: ...ain Product Warnings Safety Guidelines General Information Installation Procedure Special Application Care Cleaning Warranty Information Register your warranty at www swanstone com R e a d a n d U n d...

Page 2: ......

Page 3: ...Swanstone product s will not be damaged by the methods you choose The Swan Corporation will not be held responsible for water damage of any kind in connection with the installation of one of our Swans...

Page 4: ...situation which if not avoided may result in minor or moderate injury It may also be used to alert against unsafe practices Lifting Hazard According to the National Institute for Occupational Safety a...

Page 5: ...s work in a well ventilated area Always use an OSHA approved dust mask when cutting drilling or sanding Swanstone products Power Tool Hazard To prevent personal injury or possible death always follow...

Page 6: ...bathtub clips Confirm that all parts of this kit have been included before beginning installation Unpackaging This product is shipped to you or your retail center after careful inspection After purcha...

Page 7: ...t film waxes or any other residues Disclaimer The information contained in this Installation Manual is given free of charge It is based upon technical data which we believe to be reliable and is inten...

Page 8: ...nt points to ensure a smooth installation Completely read and understand this manual and the appropriate bathtub solid surface wall panel installation manual prior to beginning the project Measure the...

Page 9: ...nges or filler boards etc The framework depth must be at least 3 16 more than the actual depth measurement of the bathtub The illustration below shows a framework depth of 31 1 2 which is greater than...

Page 10: ...the bathtub installation is complete install 1 2 moisture resistant wall board over the existing wall surface as shown 2 The Swanstone or alternate shower wall material will be installed over the new...

Page 11: ...e Improper installation will void the warranty 1 Refer to the plumbing fixture manufacturers instructions Install any portion of the drain or overflow hardware required prior to bathtub installation 2...

Page 12: ...support by the existing subfloor eliminating bathtub flex during normal use This product is not designed for above the floor mounting the base of the bathtub must be fully supported by the subfloor An...

Page 13: ...ng subfloor This product is not designed for above the floor mounting the base of the bathtub must be fully supported by the subfloor Any application other than that covered in this manual will void t...

Page 14: ...he bathtub installation is now complete DO NOT discard these instructions PLEASE LEAVE THEM WITH THE HOMEOWNER Care and Cleaning The BT 3060 Bathtub is made of Natural Gloss Composite reinforced polye...

Page 15: ...le to a product defect or to the repair or exchange of a defective product Limited Lifetime Warranty Veritek Bathtubs LIMITED WARRANTY FOR COMMERCIAL APPLICATIONS If a Swanstone product covered by thi...

Page 16: ...ese Installation Instructions for future reference They provide important information on cleaning maintenance and surface repair of the Swanstone Wall Systems and Panels www swanstone com Form BT 3060...

Reviews: