background image

16

SPARES

The following spares are available via our web site:

SAC16810N01 - air filter
SAC16810N02 - outlet hose

www.swan-brand.co.uk

WARRANTY

This product is guaranteed for 2 years from the date of original purchase. If any defect arises due to faulty 
materials of workmanship the faulty products must be returned to the place of purchase. Refunds or 
replacement is at the discretion of the store.

The following conditions apply:

• 

The product must be returned to the retailer with proof of purchase.

• 

The product must be installed and used in accordance with the instructions contained in this 
instruction guide. 

• 

It must be used only for domestic purposes. 

• 

It does not cover wear and tear, damage, misuse or consumable parts. 

• 

Swan Products Ltd has limited liability for incidental or consequential loss or damage.

• 

This guarantee is valid in the UK and Eire Only.

DISPOSAL OF UNIT

Appliances bearing the symbol shown   here may not be disposed of in domestic rubbish. You   
are required to dispose   of old electrical  and  electronic   appliances like   this   separately.   
Please  visit  www.recycle-more.co.uk  or  www.recyclenow.co.uk for access to information 
about the recycling of electrical items. Please visit www.weeeireland.ie for access to information 
about the recycling of electrical items purchased in Ireland. The WEEE directive, introduced in 

August 2006, states that all electrical items must be recycled, rather than taken to landfill. Please arrange 
to take this appliance to your local Civic Amenity site for recycling, once it has reached the end of its life. 

SAC16810N_IM.indd   16

27/03/2020   11:11

Summary of Contents for activair SAC16810N

Page 1: ...Portable Air Conditioner Model SAC16810N Help line 0333 220 6050 SAC16810N_IM indd 1 27 03 2020 11 11...

Page 2: ...more than 35 when moving it 4 Handle the device with care 5 Keep your air conditioner at least 1 meter away from other electronic devices to avoid the risk of electromagnetic interference 6 To avoid o...

Page 3: ...6 Always remove the plug from the outlet when not in use 17 A thermal magnetic breaker or 16 amp safety fuse must be installed upstream of the main switch of your appliance 18 The product must be inst...

Page 4: ...refrigerant gas R290 is a refrigerant gas that complies with European environmental directives Do not pierce any part of the refrigerant circuit If the appliance is installed used or stored in a non v...

Page 5: ...rson specified in the use of flammable refrigerants WARNING Before putting your air conditioner into operation it must have been kept upright for at least 2 hours Description Portable Air Conditioner...

Page 6: ...contains impor tant information User Manual Identify the location where the user manual is stored or iden tify information about the instructions for use Indicate that the operating instruc tions mus...

Page 7: ...Castors 4 Handle 5 Continuous drainage water outlet 6 Cable rack 7 Water purge outlet 8 Air inlet grille evaporator 9 Hot air outlet 10 Air inlet grille condenser CONTROL PANEL 1 On Standby 2 Mode 3 S...

Page 8: ...luded Used batteries must be disposed of safely Dispose them in collection bins pro vided check with your dealer to protect the environment Respect the polarities and when inserting them INSTALLATION...

Page 9: ...avoid overheating the appliance a minimum distance of 50 cm between the appliance and the wall or any other obstacle must be respected Also make sure the hot air vents are not obstructed and the hose...

Page 10: ...is switch on the display shows the target temperature 2 MODE SELECTION The buttons on the control panel or on the remote control allow you to select one of the 3 modes Cooling Dehumidification Fan Se...

Page 11: ...ode Windows and doors must be kept closed Continuous drainage can be achieved by connecting a drain hose to the back of the unit c FAN Mode When the VENTILATION mode is selected the air circulates in...

Page 12: ...r is programmed even when the unit is off the display shows the number of hours remaining before the unit turns on automatically 6 WATER TANK FULL WATER FULL The alarm light indicates that the water t...

Page 13: ...ollect water Remove the cap to let the water out Once all the water has drained replace the plug Rubber stopper C MAINTENANCE OF THE AIR FILTER For best efficiency the air filter should be cleaned aft...

Page 14: ...rs require that doors and windows in the room remain closed The level of cooling from air conditioners depends on the following factors The size of the room If the room is too large the air conditione...

Page 15: ...r target tempera ture if required The device works but doesn t produce cold air Check target tempera ture is not higher than room temperature Lower target tempera ture Check if a door or window is not...

Page 16: ...suse or consumable parts Swan Products Ltd has limited liability for incidental or consequential loss or damage This guarantee is valid in the UK and Eire Only DISPOSAL OF UNIT Appliances bearing the...

Page 17: ...17 NOTES SAC16810N_IM indd 17 27 03 2020 11 11...

Page 18: ...18 NOTES SAC16810N_IM indd 18 27 03 2020 11 11...

Page 19: ...19 NOTES SAC16810N_IM indd 19 27 03 2020 11 11...

Page 20: ...ducts Ltd PO Box 3117 Stoke on Trent ST4 9GD Est 1 931 We love what we do s 2year GUARANTEE we re proud of our quality Scan this QR code to hear about our story Find us on Facebook on selected product...

Reviews: