Air-Actuated Hydraulic Swaging Unit (AHSU)

 Setup and Operating Instructions

Swagelok—TM Swagelok Company 
© 2002 - 2021 Swagelok Company 
Printed in U.S.A
MS-12-38 RevD, October 2021

Troubleshooting

Symptom

Causes

Remedy

Tubing is difficult to remove from 

the AHSU after preswaging.

Tubing wall may be below 

recommended minimum wall 

thickness.

Gently rock the tubing back and forth to remove it. 
Use tubing that is thicker than the minimum 
recommended wall thickness. 
 

 

 

CAUTION! 

Do not rotate the tubing.

The indicator knob does not 

release.

Improper inlet pressure being used for 

tubing material and size.

Adjust inlet pressure to the correct value for the tubing 
size and material.

Oil is leaking from unit.

Return the unit to your independent Swagelok sales 
and service representative.

The front edge of the Swagelok 

nut does not line up with the 

groove on the outside of die 

head.

Improper die head being used.  

The ferrules are not oriented properly.

Use the proper die head. 

 

Place the ferrules in proper orientation.

The unit fails to swage 

sufficiently as indicated by the 

gap inspection gauge after 

assembly.

The working pressure is too low.

Verify the working air pressure is set to the appropriate 

pressure recommended on the air input decal. 

 

 

 

CAUTION! 

Do not swage a tube more than once.

Warranty Information

Swagelok products are backed by The Swagelok Limited 
Lifetime Warranty. For a copy, visit swagelok.com or contact 
your authorized Swagelok representative.

The AHSU cannot be used for alloy 2507 tubing or for medium-pressure tubing.

Refer to Swagelok 

Gaugeable Tube Fittings and Adapter 

Fitting

 catalog, 

MS-01-140

, for additional information.

Refer to Swagelok 

Tube Fitters 

manual, 

MS-13-03

, for 

additional information.

Refer to Swagelok 

Tubing Data 

catalog, 

MS-01-107

, for 

additional information.