background image

-12-

Setting Ring-back Tone

If allow ring-back tone, press the call button to call monitor, a ring-back call tone can be heard 
from door station.
There are 3 ring-back call tones, 

Ringing one time

,

Ringing continuously 

and

 No ring-back 

tone

Ringing one time is default, to change the setting, please follow the steps:

Setting Night View LED Illumination Mode

There are 3 working modes for night view LED indicator, 

Normally on

,

Normally off 

and

 Auto

Auto is default, to change the setting, please follow the steps:

SETUP INSTRUCTIONS

UNLOCK Indicator:ON
TALK Indicator:OFF

Buzzer

Beep+, Beep

In standby mode, press 

KEY_SET

 button 

three 

times

.

UNLOCK Indicator:ON
TALK Indicator:OFF

Buzzer

Beep+

Press 

KEY_4 

button to set 

the night view LED mode 

to

 Normally on

.

UNLOCK Indicator:ON
TALK Indicator:OFF

Buzzer

Beep, Beep

Press 

KEY_4 

button again

to set the night view LED 

mode to

 Normally off

.

UNLOCK Indicator:ON
TALK Indicator:OFF

Buzzer

Beep, Beep,Beep

Press 

KEY_4 

button again

and again to set the night 

view LED mode to

 Auto

.

Press 

KEY_4

UNLOCK Indicator:ON
TALK Indicator:ON

Buzzer

Beep+, Beep

In standby mode, press 

KEY_SET

 button 

four 

times

.

UNLOCK Indicator:ON
TALK Indicator:ON

Buzzer

Beep+

Press 

KEY_1 

button to set 

the ring-back call tone ringing

one time.

UNLOCK Indicator:ON
TALK Indicator:ON

Buzzer

Beep, Beep

Press 

KEY_1 

button again

to set the ring-back call tone 

ringing continuously.

UNLOCK Indicator:ON
TALK Indicator:ON

Buzzer

Beep, Beep,Beep

Press 

KEY_1 

button again

and again to close ring-back

call tone.

Press 

KEY_1

• 

If setting mode has not been exited, you can change the night view LED illumination mode by pressing

KEY4 circularly.

• 

The 

LED_NAME

 indicator will blink all the time until exit out the setting mode.

• 

If without any operation in 10 seconds, it will exit out setting mode automatically.

• 

In this step,press 

KEY_SET

 button twice to exit out the setting mode manually.

• 

If setting mode has not been exited, you can change the ring-back tone by pressing KEY1 circularly.

• 

The 

LED_NAME

 indicator will blink all the time until exit out the setting mode.

• 

If without any operation in 10 seconds, it will exit out setting mode automatically.

• 

In this step,press 

KEY_SET

 button once to exit out the setting mode manually.

Summary of Contents for 2W12300

Page 1: ...RF CARD RF CARD RF CARD 2W12300 2W12310 2W12320 User Manual SVT MF2 Outdoor Station A B C Please read this user manual prior to installing the system and keep it well for future use ...

Page 2: ...ode 8 Setting Camera Resolution 10 Setting Unlock Mode 10 Setting Unlock Time 11 Setting Nameplate Illumination Mode 11 Setting Night View LED Illumination Mode 12 Setting Ring back Tone 12 Setting Image Display Mode 13 Registering ID Card 14 WIRING 17 Connecting Electric Lock 17 Connecting Basic One to one 18 Connecting Multi Door Stations 18 Connecting Multi Monitors 19 APPENDIX 21 Precautions 2...

Page 3: ...TIONS 11 10 9 1 3 4 8 7 6 5 12 13 2 1 Microphone 2 UNLOCK indicator 3 CALL indicator 4 Call button 5 Nameplate 6 Front panel 7 Speaker 8 Night view LED 9 Camera lens 10 Rainy cover 11 Mounting hook 12 Connection port 13 Screw hole ...

Page 4: ... 3mm 1 Connect the cable correctly 2 Drill holes in the wall to match the size of screw stoppers then attach the rainy cover and main unit to the wall and the distance between the top of main unit and rain cover should be not less than 3mm 3 Install the name plate 4 Attach the front panel to the main unit 5 Use the special screwdriver and the screws to fix the panel Surface mounted The installatio...

Page 5: ...locks L1 L2 Connect to the bus line no polarity PL External lock power input connect to the power positive power S Lock power output S Lock power output connect to the power input of locks only when using the door station to power the locks if using the external power supply for the locks the S will not be connected 1 2 3 Lock Control Jumper PIR Motion Detector Connect Port 12V GND PIR L1 L2 PL S ...

Page 6: ...Please note that this function requires the monitor with fisheye function to support The angle view is 1700 visitors in this angle view can be seen clearly and can be zoomed to see individuals up close via indoor monitor with fisheye function The door station is equipped with a terminal to connect external motion detector If the external motion detector is connected to the system following functio...

Page 7: ...r Order Setting items Setting range Default value 1 Setting door station address 0 3 0 2 Setting door station calling mode Standard Group calling mode Standard calling mode 3 Setting camera resolution High Low High 4 Setting the unlock mode 0 opened 1 closed 0 opened 5 Setting the unlock time 01 to 99 seconds 1 seconds 6 Setting the nameplate illumination mode On Off Auto On 7 Setting night view L...

Page 8: ...OFF TALK Indicator OFF Buzzer Beep Beep UNLOCK Indicator OFF TALK Indicator OFF Buzzer Beep Beep Beep UNLOCK Indicator OFF TALK Indicator OFF Buzzer Beep Beep Beep Beep ID 0 1st door station ID 1 2nd door station ID 2 3rd door station ID 3 4th door station SETUP INSTRUCTIONS If setting mode has not been exited you can change the address of door station by pressing KEY1 4 freely The LED_NAME indica...

Page 9: ...h address 02 by default Call buttonC call the monitor with address 03 by default Call buttonD call the monitor with address 04 by default Call buttonA Call all monitors in group address from 00 15 one of the monitor should be set to 00 Call buttonB C D Call all monitors in group address from 16 31 one of the monitor should be set to 16 UNLOCK Indicator OFF TALK Indicator ON Buzzer Beep Beep In sta...

Page 10: ...mode press KEY_SET button three times UNLOCK Indicator ON TALK Indicator OFF Buzzer Beep Press KEY_1 button to set the unlock mode to Normally opened UNLOCK Indicator ON TALK Indicator OFF Buzzer Beep Beep Press KEY_1 button again to set the unlock mode to Normally closed Press KEY_1 SETUP INSTRUCTIONS If setting mode has not been exited you can change the camera resolution by pressing KEY2 circul...

Page 11: ...tion mode to Normally on UNLOCK Indicator ON TALK Indicator OFF Buzzer Beep Beep Press KEY_3 button again to set the nameplate illumina tion mode to Normally off UNLOCK Indicator ON TALK Indicator OFF Buzzer Beep Beep Beep Press KEY_3 button again and again to set the nameplate illumination mode to Auto Press KEY_3 When entering time delayed setting the buzzer sound one time every second The LED_N...

Page 12: ...o Auto Press KEY_4 UNLOCK Indicator ON TALK Indicator ON Buzzer Beep Beep In standby mode press KEY_SET button four times UNLOCK Indicator ON TALK Indicator ON Buzzer Beep Press KEY_1 button to set the ring back call tone ringing one time UNLOCK Indicator ON TALK Indicator ON Buzzer Beep Beep Press KEY_1 button again to set the ring back call tone ringing continuously UNLOCK Indicator ON TALK Indi...

Page 13: ...When answering the call image switching reminder is not effective Zoom mode When answering the call the image will be displayed on full screen for 5 sec onds then switch to Zoom image to remind to enter talking status UNLOCK Indicator ON TALK Indicator ON Buzzer Beep Beep In standby mode press KEY_SET button four times UNLOCK Indicator ON TALK Indicator ON Buzzer Beep Press KEY_2 button to set the...

Page 14: ...izing master cards By default there are two master cards marked MASTER CARD ADD and MASTER CARD DELETE but you should know that the master card can be authorized by users at any time That means any two user cards can be authorized to master cards When registered new master cards the old master cards will be invalid automatically SETUP INSTRUCTIONS If setting mode has not been exited you can change...

Page 15: ...ll exit out setting mode automatically If current access is controlled by door station next access switching setting is controlled by DT ACC UNLOCK Indicator Blink two times TALK Indicator OFF Buzzer Beep Beep Show the first card to ID card window set the card of MASTER CARD ADD UNLOCK Indicator Blink three times TALK Indicator OFF Buzzer Beep Beep Beep Show the second card to ID card window set t...

Page 16: ...sequence UNLOCK Indicator OFF TALK Indicator OFF Buzzer Beep Beep Show the master card of MASTER CARD DELETE again to exit UNLOCK Indicator ON TALK Indicator OFF Buzzer Beep Beep Show the master card of MASTER CARD DELETE to ID card window in standby UNLOCK Indicator ON TALK Indicator ON Buzzer Beep Beep UNLOCK Indicator Blink for some time TALK Indicator Blink for some time Buzzer Beep Show the m...

Page 17: ...m Exit Button EB 5 The Unlock Mode must be set to 0 by default 1 The external power supply must be used according to the lock 2 The inside relay contact is restricted to 230Vac 1A or 24Vdc 1A 3 The jumper must be taken off before connecting 4 Setup the Unlock Mode according to different lock types Power on to unlock type Unlock Mode 0 by default Power off to unlock type Unlock Mode 1 EB LOCK Jumpe...

Page 18: ...s BUS IM BUS DS L1 L2 PL S S ID 0 1 2 3 4 5 6 ON DIP L2 L1 DIP Switches RF CARD SVT 2 PC6 AC 100 240VAC 100 240VAC SVT 2 DBC4 A B C D OFF ON Impedance switch BUS IM BUS DS SVT 2 PC6 AC ID 0 1st door station ID 1 2nd door station ID 2 3rd door station ID 3 4th door station L1 L2 PL S S L1 L2 PL S S L1 L2 PL S S L1 L2 PL S S To monitors RF CARD RF CARD RF CARD RF CARD The door station work in Standa...

Page 19: ...is more than 4 monitors in villa Refer to Page 9 ID 0 Code 1 DIP6 off Optional functional module SVT 2 SCU camera module max 4 SVT 2 GSM module mobile phone transfer SVT 2 TPS module PBX transfer Master Code 1 DIP6 off Slave 2 Code 1 DIP6 on Slave 3 BUS IM BUS DS PC6A AC 100 240VAC Code 1 DIP6 off Slave 1 RF CARD SCU GSM TPS ...

Page 20: ...DBC4A1 OFF ON Impedance switch BUS IM BUS DS Code 1 DIP6 on Code 2 DIP6 on Code 3 DIP6 on Code 4 DIP6 on ID 0 RF CARD PC6A AC 100 240VAC Optional functional module BDU SVT 2 BDU bus amplifier module SVT 2 RLC staircase light controller module SVT 2 DBC4 2 4 inputs branch distributor Parallel Connection With SVT 2 DBC4 in Standard Mode ...

Page 21: ...age inside the products please refer service only to a trained and qualified professional APPENDIX Power supply Power consumption Camera lens Lock Power supply Number of relay circuits Mounting Working temperature Protection Material Wiring Dimension DC 24V Standby 0 8W Working 3W Color CMOS 2 0 Mega pixel 1 2 7 fisheye camera 1700 wide angle 12Vdc 280mA Internal Power 2 the second lock need exter...

Page 22: ...imited in the DT system Using different cables may also affect the maximum distance which the system can reach Cable and distance unit m Cable Usage A B 2 IM B 16 IM Twisted cable 2x0 75mm2 60 100 40 Twisted cable 2x1mm2 80 120 60 A B RF CARD SVT 2 PC6 Basic IN OUT Wiring Mode ...

Page 23: ... 23 B A C 2 2 SVT 2 DBC4 RF CARD SVT 2 PC6 Cable and distance unit m Cable Usage A B C Twisted cable 2x0 75mm2 60 60 30 Twisted cable 2x1mm2 80 80 40 APPENDIX Parallel Connection Mode With SVT 2 DBC4 ...

Page 24: ...The design and specifications of this user manual can be changed without any notification to the user All copyright and interpretation rights are reserved to SVT Innovations Inc ...