SVS 01278.40 Operating Instructions Manual Download Page 13

Time

Number / Position

1

2

3

4

5

6

3600 s

ON

ON

ON

ON

X

OFF

1800 s

OFF

ON

ON

ON

X

OFF

900 s

ON

OFF

ON

ON

X

OFF

450 s

OFF

OFF

ON

ON

X

OFF

225 s

ON

ON

OFF

ON

X

OFF

112 s

OFF

ON

OFF

ON

X

OFF

56 s

ON

OFF

OFF

ON

X

OFF

28 s

OFF

OFF

OFF

ON

X

OFF

14 s

ON

ON

ON

OFF

X

OFF

7 s

OFF

ON

ON

OFF

X

OFF

3,5 s

ON

OFF

ON

OFF

X

OFF

1,7 s

OFF

OFF

ON

OFF

X

OFF

0,8 s

ON

ON

OFF

OFF

X

OFF

0,4 s

OFF

ON

OFF

OFF

X

OFF

0,2 s

ON

OFF

OFF

OFF

X

OFF

0,1 s

OFF

OFF

OFF

OFF

X

OFF

permanent

X

X

X

X

X

ON

X = don´t care

On = slide in the direction of the arrow

Off = slide against the direction of the arrow

- 13 -

Summary of Contents for 01278.40

Page 1: ...elektrische Anlagen und Betriebsmittel zu beachten In Schulen Ausbildungseinrichtungen Hobby und Selbsthilfewerkst tten ist das Betreiben des Produkts durch geschultes Personal verantwortlich zu berw...

Page 2: ...igen Schiebeschaltern werden die Funktionen zugeordnet so dass gegenseitige Verriegelungen oder mehrere Kan le mit einer Taste geschalten werden k nnen Ein Kanal mit Tastfunktion wird durch die kleins...

Page 3: ...tisch konfiguriert Diese Funktion ist kompatibel zu Sendern ab der Version HSV xx 20 Jeder Lernmodus wird automatisch verlassen wenn ein Sender oder eine Taste erfolgreich eingelernt wurde wenn sich d...

Page 4: ...scheinbares Prellen zu vermeiden W hrend der ablaufenden Timerzeit wird kein erneuter Befehl ausgef hrt Dauerhaft Einschalten oder gro e Timerzeiten d rfen hierbei also nicht eingestellt werden Draht...

Page 5: ...hat could put human life at risk by using radio connection there is always present a potential hazard due to extraneous disturbances The Operating Instructions need to be followed at all times 2 Safet...

Page 6: ...attached table The relay remains closed as long as the transmitter key stays activated For applications where for example inductances produce signal glitches due to electromagnetic interference durin...

Page 7: ...ERASE button for at least 3s again to clear the whole list of learned transmitters Check for error free operation of the receiver by pressing the transmitter buttons desired The state of each relay is...

Page 8: ...circuit to indicate the status of relay 4 is shown to the right Use only with the internal 10V because of parallel use for relay control Antenna The SHR 12 K4 is equipped with its optimised integral a...

Page 9: ...auvaise manipulation ou du non respect des instructions La garantie en sera caduque Pour des raisons de s curit et d agr ments CE il est proscrit de modifier ou de transformer l appareil Tout particul...

Page 10: ...elais correspondant colle alors uniquement pendant l appui sur la touche de l metteur Pour les applications comportant par exemple la commutation de charges inductives susceptibles de cr er des pertur...

Page 11: ...s la proc dure d apprentissage est une liste satur e un metteur ou une touche d j configur s Apr s avoir termin la proc dure d apprentissage tester la fonction du relais gr ce aux LEDs de contr le c t...

Page 12: ...ex En liaison avec des verrouillages cl n utiliser qu avec 10V car ce circuit transistors prend simultan ment le contr le des relais L antenne Le r cepteur SHR 12 K4 est quip d une antenne int gr e pe...

Page 13: ...F 56 s ON OFF OFF ON X OFF 28 s OFF OFF OFF ON X OFF 14 s ON ON ON OFF X OFF 7 s OFF ON ON OFF X OFF 3 5 s ON OFF ON OFF X OFF 1 7 s OFF OFF ON OFF X OFF 0 8 s ON ON OFF OFF X OFF 0 4 s OFF ON OFF OFF...

Page 14: ...dio Equipment Directive RED 2011 65 EU Restriction of Hazardous Substances RoHS und dass die nachstehenden harmonisierten europ ischen Normen zur Anwendung gelangt sind and that the following harmoniz...

Reviews: