Users Manual Area Scan Cameras svs11002 and svs16000
Page 42
“I<ENTER>“: out put of factory (default) data (like ser. # of product)
KAI11002
Serial no.: 0527
Hardware version 1.0
Firmware version 1.0
Software version 1.0
Gain1: 007C
; factory setting gain tap 1(= gain factor 1.0)
Gain2: 0077
; factory setting gain tap 2 (= gain factor 1.0)
Offset1: 0008
; factory setting offset tap 1
Offset2: 0008
; factory setting offset tap 2
OK
“O<Channelnr.>, <Hexvalue><ENTER>“:
Input of dark offset for the appropriate output tap
0.3FF
“G<Chanelnr.>, <Hexvalue><ENTER>“:
Input of gain for the appropriate output tap
0.2FF, gain = n * 0.045dB
“T<Hexvalue><ENTER>“:
Input of exposure time in line times
0.FFFF in triggered mode
0.815 in free running mode, exposure time in line times
is 816 (= line count of one frame) - n
“D<Hexvalue><ENTER>“:
Input of amount of lines which are dumped out (partial scan mode)
0,2 14 A
0 = no partial scan
1 = not allowed
2 = 2 * 15(decimal) lines dumped out
n = n * 15(decimal) lines dumped out
valid lines = 2704 - (n * 15)
n = (2672 - valid lines)/15
(formula with decimal values)
“S<ENTER>“: safes actual configuration to EEPROM
“R<ENTER>“: camera reset, output of status message
“M<Hexvalue><ENTER>“: Input of operation mode
Summary of Contents for CameraLink svs11002
Page 2: ...Users Manual Area Scan Cameras svs11002 and svs16000 Page 2 ...
Page 10: ...Users Manual Area Scan Cameras svs11002 and svs16000 Page 10 This page is left blank ...
Page 17: ...Users Manual Area Scan Cameras svs11002 and svs16000 Page 17 ...
Page 26: ...Users Manual Area Scan Cameras svs11002 and svs16000 Page 26 View on mounting side svs16000 ...