activated due to protective function.   

Repair method:   

The first is to identify the cause of failure. After the action of temperature limiter due to boiling is 

excluded, repairman shall check internal connection line. If the insulation layer is found black or with 

obvious corrosion, it needs to replace the internal connection line and even temperature limiter. Then, 

it needs  to measure the contact resistance between input/output end of temperature limiter; if it is 

greater  than  50m  Ω,  it  is  suggested  to  replace  the  temperature  limiter  and 

return it to factory for 

verification. To replace it with a snap-action temperature limiter, it needs to cover a layer of heat 

conducting silica gel between temperature limiter and heating pipe, so as to ensure the good heat 

conduction. Generally, this problem can be solved by replacement of temperature controller or guiding 

user to correctly use the machine.   

(IV) Fault analysis and troubleshooting for shower head without water flow or little water   

The shower without water flow or little water results from low water pressure, shutdown of water and 

other external reason, or blocking of internal outlet pipe. To solve such problems, repairman shall first 

exclude the cause of external water supply and then solve the problem one by one according to the 

following procedures:   

Repair method:   

1.

 

Unscrew shower head, open water inflow valve and observe whether water drain is better, 

because the eroded substance and water scale from consumed magnesium rods after long-term 

use are prone to block shower head and reduce water yield;   

2.

 

Loosen safety valve slightly and open water inflow valve. If it is normal at this moment, it shall 

be identified that excessive tightness of safety valve forces the inlet of inner compartment to hold 

down the internal relief spring of safety valve, so the repairman only needs to loosen it and seal it 

with  thread seal  tape; if there is no water flow, it needs to unscrew safety valve and directly 

connect inlet pipe to inner compartment, open water inflow valve and observe whether the water 

drain is normal. If it is normal, it may be judged as a failure of safety valve. The space of safety 

valve is relatively smaller, so it is easily blocked by silt and thread seal tape. In such a case, it 

only needs to dismount and clean it;   

3.

 

If it is not attributed to shower head and safety valve, it needs to use a slender iron wire to clear 

away the outlet pipe. Generally, the problem can be solved.   

(V)  Replacement of heater   

1.

 

Open the repair cover   

Dismount all screws fastening the repair cover (the quantity and location of screws is varying 

Summary of Contents for SVTE100A3

Page 1: ...svan SVTE30A3 SVTE50A3 SVTE80A3 SVTE100A3 SERVICE MANUAL MANUAL DE SERVICIO...

Page 2: ...c expanding tube 3 Adjustable wrench Used to install fastening screws 4 Screwdriver Used to install fastening screws 5 Tubing cutter or hacksaw or Used to cut and cut off all pipe fittings 6 Round mak...

Page 3: ...ustible gas leak and a place of storage for flammable explosive and corrosive articles 2 Keep away from a position with high magnetic field and effect of electric field preventing magnetic field affec...

Page 4: ...ht capacity of installation holders is not less than the weight twice as much as the normal state Meanwhile the installation holder must be rust proofing Generally consideration is given to combinatio...

Page 5: ...wind and rain III Information checkup Check the user s purchase invoice and the model as listed in packing case and secure the consistency between invoice and product In case of any inconsistency the...

Page 6: ...ile wall the installer shall as far as possible maintain holes at tile seams so as to ensure precise location and prevent excessive and incorrect drilling holes II Positioning and punching First confi...

Page 7: ...allation 1 Planning Figuring out the routing plan of piping layout according to installation position and water use point and then make it confirmed by the user 2 Pipe arranging Cut pipes upon needs a...

Page 8: ...ed cold water but it is not allowed to power it on or insert the plug before cold water outflows continuously from the shower head 3 After the water heater is filled with water the installer shall clo...

Page 9: ...if any replace it with new cable Otherwise it may result from electrical leakage of water heater so the water heater shall be replaced Display E2 Water shortage of inner compartment leading to boiling...

Page 10: ...lace circuit board or temperature controller Otherwise it needs to replace the heater because contact between temperature tube and heating pipe or water scale cause badness of thermal transmission No...

Page 11: ...s damage of heater then check whether the rest button in the middle of temperature limiter trips out if yes reset it correspondingly then check whether temperature controller and switch work normally...

Page 12: ...mponents etc Repair method 1 Observe whether there is sign of water leakage from the shell If there is water stain at the end cap beyond the scope of repair it is preliminarily judged as water leakage...

Page 13: ...ls of temperature limiter results in electric overheating and thus activate temperature limiter Additionally drifting temperature point of temperature controller results in excessive temperature that...

Page 14: ...the cause of external water supply and then solve the problem one by one according to the following procedures Repair method 1 Unscrew shower head open water inflow valve and observe whether water dr...

Page 15: ...d screw bolts fastening the flange Dismount five M8 nuts with a 12mm hexagon socket 4 Disassemble flange pressing plate Use a screwdriver and other tools to unclench the flange pressing plate at the c...

Page 16: ...m quina y la tuber a 12 Martillo Utilizado para golpear e instalar correctamente la expanis n de tubo de pl stico 13 Llave Para instalar los tornillos de fijaci n 14 Destornillador Used to install fas...

Page 17: ...lapiz Para comprobar si est cargado III Materiales de instalaci n Agua caliente del tubo de PPR tuber a de agua fr a PPR pipa del codo uni n ensambladora doble pez n empalme tipo t cinta de sello del...

Page 18: ...agua con la carga completa Generalmente el calentador de agua deber ser instalado en pared de cemento o ladrillo macizo con un espesor de 24cm y su cojinete de estructura de acero puede satisfacer me...

Page 19: ...e de alimentaci n de ruta independiente La instalaci n del z calo est estrictamente prohibida El cable de alimentaci n debe estar fijo en el interruptor de ruptura de aire 5 El circuito para la instal...

Page 20: ...n I Examen visual Desplegar el empaquetado cuidadosamente y verificar si el producto est rayado deformado o abollado si la tapa final est dividida o explot y si el tubo de entrada est torcido II Insta...

Page 21: ...itud del perno de fijaci n En la perforaci n primero marcar la posici n de perforaci n con la broca de perforaci n y perforar un agujero de posici n relativamente superficial a baja velocidad y luego...

Page 22: ...disposici n de tuber as seg n la posici n de montaje y el agua utilizar punto y luego que sea confirmado por el usuario 2 Tubo arreglo cortar tuber as que se necesite y colocar seg n el dise o de la t...

Page 23: ...aplicable para los dos tipos abrir tipo y tipo cerrado XIV Gu a de puesta en servicio 1 Al terminar la instalaci n el instalador primero notificar al usuario para confirmar el efecto de la instalaci...

Page 24: ...la funci n de cada m todo de funci n y ajuste XV Limpieza y entrega Si el usuario no tiene ninguna duda sobre la terminaci n de la instalaci n y la depuraci n rellene la tarjeta de instalaci n y ofr...

Page 25: ...r sobrecalentamiento debido a un fallo del regulador de temperatura o del tablero del circuito Identificar si el regulador de temperatura es normal y luego pulsar el rearme del limitador de temperatur...

Page 26: ...nicamente el drenaje sin agua caliente se debe principalmente a una aver a en el circuito al error de la tuber a de calentamiento o al mal funcionamiento Circuito el ctrico Primero determinar si el fa...

Page 27: ...sa a la resistencia meda la resistencia para juzgar si el calentador est normal por ejemplo si la resistencia es de 1500W el calentador ser R U U P 32 3 5 Para juzgar que si expansi n hidr ulica que c...

Page 28: ...e comunicar primero al usuario la posici n aproximada de las fugas de agua y preparar los materiales y las herramientas de servicio correspondientes En general las herramientas y materiales que se req...

Page 29: ...e adas para la protecci n del compartimento interior si la ca da de agua causa alg n da o en el uso se sugiere resolver este problema a fondo mediante la instalaci n adicional de un reductor de presi...

Page 30: ...imitador de temperatura si es mayor de 50 m se sugiere reemplazar el limitador de temperatura y devolverlo a f brica para su verificaci n Para reemplazarlo con un limitador de temperatura de acci n r...

Page 31: ...jar el tubo de salida En general el problema puede ser resuelto V Replacement of heater 1 Abra la tapa de reparaci n Desmonte todos los tornillos que sujetan la tapa de reparaci n la cantidad y ubicac...

Page 32: ...n estructural del calentador 10 Instalar un nuevo calentador La operaci n es inversa al proceso de desmontaje Tenga cuidado con el bloqueo de hilo Los cinco tornillos deben atornillarse firmemente so...

Reviews: