ELECTRICAL SYSTEM 6-19
Step 2
1) Measure the battery voltage between input lead wires (O/W and B/W) at the CDI unit with the ignition
switch in the “ON” position.
Is the voltage OK?
Step 3
1) Measure the ignition coil primary peak voltage. (
6-20)
NOTE:
This inspection method is applicable only with the multi-circuit tester and the peak volt adaptor.
Is the peak voltage OK?
Step 4
1) Inspect the spark plug. (
2-7)
Is the spark plug OK?
Step 5
1) Inspect the parking brake switch. (
6-23)
Is the parking brake switch OK?
Step 6
1) Inspect the ignition coil. (
6-21)
Is the ignition coil OK?
Step 7
1) Measure the pick-up coil peak voltage and resistance. (
6-21 to -22)
NOTE:
The pick-up coil peak voltage inspection is applicable only with the multi-circuit tester and peak volt adaptor.
Is the peak voltage and resistance OK?
YES
Go to Step 3.
NO
• Faulty ignition switch.
• Faulty remote engine stop switch.
• Faulty engine stop switch.
• Broken wiring harness or poor connection of related circuit couplers.
YES
Go to Step 4.
NO
Go to Step 5.
YES
Go to Step 6.
NO
Faulty spark plug.
YES
Go to Step 6.
NO
Faulty parking brake switch.
YES
Go to Step 7.
NO
• Poor connection of the ignition coil.
• Faulty ignition coil.
YES
• Faulty CDI unit.
• Poor connection of generator coupler.
• Open circuit in wiring harness.
NO
Faulty pick-up coil.