IGNITION AND ELECTRICAL 3-7
IGNITION COIL RESISTANCE
09930-99320: Digital tester
Tester range:
Ω
(Resistance)
Primary side
1. Disconnect the ignition coil lead wire connector.
2. Connect the tester probe to the coil lead wires as shown.
Primary coil resistance: 0.2 – 0.4
Ω
If measurement is out of specification, replace the ignition coil.
Secondary side
1. Remove the spark plug caps from the high-tension cord.
2. Connect the tester probe to the high-tension cords as
shown.
Secondary coil resistance: 6.8 – 10.2 k
Ω
If measurement is out of specification, replace the ignition coil.
CDI UNIT OUTPUT
09930-89920: 6 pin connector test cord
Peak Voltmeter Stevens CD-77
Tester range: NEG 500
1. Disconnect 6 pin wire harness connector from CDI unit
2. Connect the 6 pin test cord between CDI unit and wire har-
ness as shown in figure.
3. Connect the tester probe to the test cord lead wires as
shown.
4. Remove all spark plugs.
5. Crank with the recoil starter, then measure voltage.
CDI unit output: 128 V or over
If measurement is out of specification, replace the CDI unit.
Tester probe connection
Probe
Other probe
Orange
Black
Tester probe connection
Probe
Other probe
High-tension cord
Other High-tension cord
Tester probe connection
+
(Red)
-
(Black)
Orange
{Test cord wire color: Black}
Engine body ground
O
B
CDI unit
Black