4E-18 ABS:
5
1) Connect the combination meter coupler.
2) Turn the ignition switch ON with the ABS control unit
coupler disconnected, measure the voltage between
“21” (Br) and “24” (B/W) at the coupler.
Special tool
(A): 09900–25008 (Multi circuit tester set)
Tester knob indication
Voltage (
)
Normal value (“21” – “24”)
8.0 V and more
ABS control unit coupler (Harness side)
Is the voltage between “21” and “24” normal?
Go to Step 6.
• Inspect the wire
harness. (Faulty
indicator light wire)
• Signal fuse or
indicator light is
blown.
6
1) Turn the ignition switch OFF.
2) Check for continuity between “24” (B/W) at the coupler
and body ground, also “25” (B/W) at the coupler and
body ground.
Special tool
(A): 09900–25008 (Multi circuit tester set)
Tester knob indication
Continuity (
)
ABS control unit coupler (Harness side)
Are there continuity between “24”, “25” and body ground?
Replace the ABS
control unit/HU.
Inspect the wire
harness. (Faulty ground
wire)
Step
Action
Yes
No
24
25
(
ޓ
)
18
10
12
13
16
2
3
4
21
(
ޓ
)
8
9
(A)
I718H1450037-02
24
25
18
10
12
13
16
2
3
4
21
8
9
(A)
I905H1450019-01