10
Operating and Storage Temperatures
SM-16
Operating temperature 0° C to 40° C [32° F to 104° F]
Storage temperature -20° C to 50° C [-4° F to 122° F]
SM-36
Operating and storage temperature 0° C to 40° C [32° F to 104° F]
Technical Specifi cations
The Suunto depth gauge SM-16 complies with the prEN 13319 standard.
The tolerances for depth gauges are:
At 3m
+0.8 / -0.4 m
At 6m
+0.8 / -0.4 m
At 9m
±0.8 m
At 15m
+1/ -1.2 m
At 30m
+1/ -1.2 m
At 45m
+1/ -1.5 m
At 60m
+1 / -1.5 m
The SM-36 pressure gauges comply with the EN 250 standard.
The tolerances for pressure gauges, measured at decreasing pressure are:
At 40 bar
± 5 bar
At 100 bar
± 10 bar
At 200 bar
± 10 bar
At 300 bar
± 10 bar