Optional Programmable Timer
Installation: To The Installer
1. Read the operating instructions provided with the timer.
2. Disconnect power supply prior to installation to
prevent electrical shock.
3. Damage to the contacts caused by short circuiting will void
the warranty.
4. Wire in accordance with National Electrical and Local Code
requirements.
Be sure all connections are secure.
Double check all twist-on wire connectors.
6. Mount timer into wall box using supplied screws.
7. If timer does not operate, check that the timer's black wire is connected to hot
line and not the load. If necessary, reverse connections to red and black wires
Manual Operation
The slide switch provides manual operation of the load, overriding the timer, Set to the "OFF" position,
the load will be continuously off, and if set to "ON", it will be continuously on. For automatic timed
on's and off's, the switch must be in the "AUTO" position.
Programming
The timer dial contains 72 "trippers" which, when set at the inner perimeter of the dial, will turn the
switch "ON" at the time adjacent to the tripper. The switch will return to the "OFF" position when the
timer progresses past the inward trippers.
The 72 trippers allow multiple on/off sequences with a minimum on or off timer of 20 minutes.
To program, set all trippers inward for the duration of the on event.
For example, to turn unit on at 5:00 pm and off at 11:00 pm, leave inward the 18 trippers between
5 and 11 on the "pm" side of the dial. Make sure manual switch is in the "AUTO" position.
NOTE: For any times where "OFF" programming is desired, the trippers must be moved
to the outer perimeter of the dial.
Setting the Time
Rotate the dial clockwise until the correct time and "am" or "pm" is opposite the arrow on the plate.
CAUTION: Do not turn dial counter-clockwise, as the timer will be damaged.
8
WarmaTowel
®
Installation and Operating Instruction
Wiring Diagram
LINE (black)
LOAD (red)
NEUTRAL (white)
WarmaTowel
WARNING
!